5-Megapixel C-Mount Code Reader
last update: June 12, 2023
V440-F | ||
---|---|---|
Symbologies
*1 |
1D Symbologies | Code 39, Code 128, BC412, Interleaved 2 of 5, UPC/EAN,
Codabar, Code 93, Pharmacode, PLANET, Postnet, Japanese Post, Australian Post, Royal Mail, Intelligent Mail, KIX |
2D Symbologies | Data Matrix (ECC 0-200), QR Code, Micro QR Code,
Aztec Code, DotCode, DMRE |
|
Stacked Symbologies | PDF417, MicroPDF417, GS1 Databar
(Composite and Stacked) |
|
Reading
Performance *2 |
Number of Reading Digits | No Upper Limit
(depending on bar width and reading distance) |
Reading Distance /
Field of View |
Based on Lens Selection and Code Size | |
Pitch Angle (α) *3 | ±30° | |
Skew Angle (β) *3 | ±30° | |
Tilt Angle (γ) *3 | ±180° | |
Image | Resolution, Pixel Size | 2464 (H) x 2056 (V) - 3.45 μm Pixel Size |
Color / Monochrome | Monochrome CMOS | |
Shutter | Global Shutter | |
Frames per Second | 35 FPS for 5 MP | |
Exposure | 16 μs to 400 msec | |
Image Logging | FTP | |
Trigger | External Trigger (Edge or Level), Communication Trigger
(Ethernet, RS-232C) |
|
Trigger to Strobe Latency + Jitter | 320 μs + 65 μs | |
I/O
Specifications |
Input Signals | Trigger Input, New Master, and Default -
Bi-Directional Inputs, Optoisolated, 4.5 - 28 V rated (10 mA [] 28 VDC) |
Output Signals | 3 Signals: Bi-Directional, Optoisolated, 1 - 28 V rated,
(ICE < 100 mA at 24 VDC, current limited by user) |
|
Communication | Connectivity | RS-232C, Ethernet TCP/IP, EtherNet/IP™, PROFINET |
Ethernet Specifications | 1000BASE-T | |
Indicator LEDs | LINK (Amber), PWR (Green) | |
Power Supply Voltage | Power over Ethernet (IEEE 802.3af) / 24 VDC +/- 20%,
External Input via IO *4 |
|
Current Consumption | PoE (44-57 VDC): 0.10 A or 24 VDC: 0.15 A | |
Weight | Main Body Only | Approx. 103.4 g |
Packaging Weight | Approx. 219.1 g | |
Dimensions | 40 mm (W) × 61 mm (D) × 30 mm (H) Note:
Depth measurement excludes connector |
|
Accessories | ReadMeFirst, CE Compliance Sheet,
Protocol Support Table |
|
Materials | Aluminum Diecast, Alumite (Black) | |
Software | WebLink 3.0 | |
Environmental /
Immunity *5 |
Operating Temperature | 0° to 40°C |
Storage Temperature | -25° to 65°C (No Icing or Condensation) | |
Ambient Atmosphere | No Corrosive Gases | |
Humidity
(Operating and Storage) |
5% to 95% (Non-Condensing) | |
Destructive Vibration
Resistance |
Oscillation Frequency: 10 to 150Hz,
Half Amplitude: 0.35 mm, Vibration Direction: X/Y/Z, Sweep Time: 8 Minutes / Count, Sweep Count: 10 Times |
|
Drop Specification | Impact Force: 150 m/s2, Test Direction: 6 Directions,
3 Times Each (Up / Down, Front / Behind, Left / Right) |
|
Water Resistance Rating | IP40 per IEC 60529 | |
EMC / Safety | FCC 47 CFR part 15 Subpart B, ICES-003, EN 55032,
EN 55035, AS/NZS CISPR32, CNS 13438, KN32, KN35, UL 62368-1, UL 60950-1 FCC, UL, CE, UKCA, RCM, KC *6 |
*1. These symbologies are supported based on Omron’s read capability validation standard. Omron recommends that validation be performed for each application.
*2. Unless otherwise specified, reading performance is defined with center of field of view, angle R = ∞.
*3.
*4. Code reader operates External Input at 24 VDC when supplied at the same time as PoE.
*5. In an electrically noisy environment, use only the V440-F in combination with a noise filter cable (V430-W[]F-[]M) to ensure proper operation.
*6. FCC = United States
UL = United States
CE = European Union
UKCA = Great Britain (England / Wales / Scotland)
RCM = Australia / New Zealand
KC = South Korea
last update: June 12, 2023