Smart Laser Sensors
            
        
last update: May 26, 2025
| Sensing method | Coaxial Retro-reflective with MSR function | |||
|---|---|---|---|---|
| Model | E3NC-LH03 | E3NC-LH03+
 E39-P51  | 
||
| Light source (wavelength) | Visible semiconductor laser diode (660 nm), 215 μW max. | |||
| Laser class | Class 1 (JIS, IEC/EN, FDA *1, GB/T) | |||
| Sensing
 distance *2  | 
Giga-power mode (GIGA) | 8 m | 0.5 m | |
| Standard mode (Stnd) | 6 m | |||
| High-speed mode (HS) | 3.5 m | |||
| Super-high-speed mode
 (SHS)  | 
2 m | |||
| Beam shape | Spot | Line | ||
| Beam size *3 | Approx. 2 mm dia. at 1 m | Line length: Approx. 25 mm at
 250 mm Line length: Approx. 50 mm at 500 mm  | 
||
| Differential distance *4 | --- | |||
| Indicators | OUT indicator (orange) and STABILITY indicator (green) | |||
| Ambient illumination (Receiver side) | Incandescent lamp: 10,000 lx max.,
 Sunlight: 20,000 lx max.  | 
|||
| Ambient temperature range | Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or
 condensation)  | 
|||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | |||
| Altitude | 2,000 m max. | |||
| Installation environment | Pollution degree 3 (as per IEC 60947-1) | |||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
| Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours each
 in X, Y, and Z directions  | 
|||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
| Degree of protection | IEC IP67 *5 | |||
| Connecting method | Pre-wired connector (standard length: 2 m) | |||
| Materials | Sensor Head | Case | Polybutylene terephthalate (PBT) | |
| Lens | Methacrylic resin (PMMA) | |||
| Cable | Vinyl chloride (PVC) | |||
| Lens
 Attachment  | 
Case | --- | ABS | |
| Lens | --- | Methacrylic resin (PMMA) | ||
| Weight (packed
 state/Sensor Head only)  | 
Models with 2-m cable | Approx. 120 g/approx. 70 g | ||
| Models with 5-m cable | Approx. 180 g/approx. 130 g | |||
| Lens Attachment | --- | Approx. 25 g/approx. 2 g | ||
| Accessories | Instruction Manual | |||
| Sensing method | Diffuse-reflective | Limited reflective | |||
|---|---|---|---|---|---|
| Model | E3NC-LH02 | E3NC-LH02+
 E39-P52  | 
E3NC-LH01 | ||
| Light source (wavelength) | Visible semiconductor laser diode (660 nm), 315 μW max. | ||||
| Laser class | Class 1 (JIS, IEC/EN, FDA *1, GB/T) | ||||
| Sensing
 distance *2  | 
Giga-power mode (GIGA) | 1,200 mm | 1,000 mm | 70±15 mm | |
| Standard mode (Stnd) | 750 mm | 600 mm | |||
| High-speed mode (HS) | 250 mm | 200 mm | |||
| Super-high-speed mode
 (SHS)  | 
200 mm | 150 mm | |||
| Beam shape | Spot | Line | Spot | ||
| Beam size *3 | Approx. 0.8 mm dia. at
 300 mm  | 
Line length: Approx. 45
 mm at 500 mm Line length: Approx. 100 mm at 1,000 mm  | 
Approx. 0.1 mm dia. at
 70 mm  | 
||
| Differential distance *4 | 10% of sensing distance max. | ||||
| Indicators | OUT indicator (orange) and STABILITY indicator (green) | ||||
| Ambient illumination (Receiver side) | Incandescent lamp: 10,000 lx max.,
 Sunlight: 20,000 lx max.  | 
||||
| Ambient temperature range | Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or
 condensation)  | 
||||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Altitude | 2,000 m max. | ||||
| Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
| Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours
 each in X, Y, and Z directions  | 
||||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||||
| Degree of protection | IEC IP65 (E3NC-LH02: Applies only when adjuster is locked.) *5 | ||||
| Connecting method | Pre-wired connector (standard length: 2 m) | ||||
| Materials | Sensor Head | Case | Polybutylene terephthalate (PBT) | ||
| Lens | Methacrylic resin (PMMA) | ||||
| Cable | Vinyl chloride (PVC) | ||||
| Lens
 Attachment  | 
Case | --- | ABS | --- | |
| Lens | --- | Methacrylic resin
 (PMMA)  | 
--- | ||
| Weight (packed
 state/Sensor Head only)  | 
Models with 2-m cable | Approx. 115 g/approx. 65 g | |||
| Models with 5-m cable | Approx. 175 g/approx. 125 g | ||||
| Lens Attachment | --- | Approx. 25 g/approx. 2 g | --- | ||
| Accessories | Instruction Manual | ||||
| Type | Standard models | Model for Sensor
 Communications Unit  | 
|||
|---|---|---|---|---|---|
| NPN output | E3NC-LA21 | E3NC-LA7 | E3NC-LA24 | E3NC-LA0 | |
| PNP output | E3NC-LA51 | E3NC-LA9 | E3NC-LA54 | ||
| Connecting method | Pre-wired | Wire-saving
 Connector  | 
M8
 Connector  | 
Connector for Sensor
 Communications Unit  | 
|
| Inputs/
 outputs  | 
Outputs | 2 outputs | 1 output | --- *1 | |
| External inputs | 1 input | ||||
| Power supply voltage *2 | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the
 connector through the Sensor Communications Unit  | 
|||
| Power consumption *3 | At Power Supply Voltage of 24 VDC
 Normal mode: 1,560mW max. (Current consumption: 65mA max.) Eco ON: 1,320 mW max. (Current consumption: 55 mA max.) Eco LO: 1,440 mW max. (Current consumption: 60 mA max.)  | 
||||
| Control outputs *4 | Load power supply voltage: 30 VDC max.,
 open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max.  | 
--- | |||
| External inputs | Refer to *5. | --- | |||
| Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs)  | 
||||
| Protection circuits | Power supply reverse polarity protection,
 output short-circuit protection, and output reverse polarity protection  | 
Power supply reverse
 polarity protection and output short-circuit protection  | 
|||
| Response
 time  | 
Super-high-speed mode (SHS) *6 | Operate or reset: 80 μs | |||
| High-speed mode (HS) | Operate or reset: 250 μs | ||||
| Standard mode (Stnd) | Operate or reset: 1 ms | ||||
| Giga-power mode (GIGA) | Operate or reset: 16 ms | ||||
| Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning,
 or percentage tuning (-99% to +99%)), or manual adjustment.  | 
||||
| Maximum connectable Units | 30 | With E3NW-ECT: 30 units *7
 With E3NW-CRT: 16 units With E3NW-CCL: 16 units  | 
|||
| No. of Units
 for mutual interference prevention  | 
Super-high-speed mode (SHS) *6 | 0 | |||
| High-speed mode (HS) | 2 | ||||
| Standard mode (Stnd) | 2 | ||||
| Giga-power mode (GIGA) | 4 | ||||
| Functions | Dynamic power control (DPC) | Provided | |||
| Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms  | 
||||
| Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
| Resetting settings *8 | Select from initial reset (factory defaults) or user reset (saved settings). | ||||
| Eco mode *9 | Select from OFF (digital display lit), ECO ON (digital display not lit), and ECO LO (digital display dimmed). | ||||
| Bank switching | Select from banks 1 to 4. | ||||
| Power tuning | Select from ON or OFF. | ||||
| Output 1 | Select from Normal Detection Mode or Area Detection Mode. | ||||
| Output 2 | Select from
 normal detection mode, alarm output mode, or error output mode.  | 
--- | Select from normal
 detection mode, alarm output mode, or error output mode.  | 
||
| External input | Select from input OFF, tuning, power tuning,
 laser OFF, zero reset, or bank switching.  | 
--- | |||
| Hysteresis width | Select from standard setting or user setting. | ||||
| Ambient temperature range* | Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation)  | 
Operating:
 Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C, Storage: -30 to 70°C (with no icing or condensation)  | 
|||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Altitude | 2,000 m max. | ||||
| Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
| Insulation resistance | 20 MΩ (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
| Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150m/s2 for 3 times each in
 X, Y, and Z directions  | 
|||
| Weight (packed state/Amplifier Unit only) | Approx. 115 g/
 approx. 75 g  | 
Approx. 60 g/
 approx. 20 g  | 
Approx. 65 g/approx. 25 g | ||
| Materials | Case | Polycarbonate (PC) | |||
| Cover | Polycarbonate (PC) | ||||
| Cable | Vinyl chloride (PVC) | ||||
| Accessories | Instruction Manual | ||||
            *1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
      PLC operation via Communications Unit enables reading detected values and changing settings.
*2. Applicable Sensor Head is the series of E3NC-LH[][].
*3. At Power Supply Voltage of 10 to 30 VDC.
      Normal mode: 1,650 mW max. (Current consumption: 55 mA max. at 30 VDC, 115 mA max. at 10 VDC)
      Eco ON: 1,410 mW max. (Current consumption: 47 mA max. at 30 VDC, 95 mA max. at 10 VDC)
      Eco LO: 1,530 mW max. (Current consumption: 51 mA max. at 30 VDC, 105 mA max. at 10 VDC)
*4. The total for both outputs of a model with 2 outputs is 100 mA max.
      (Residual voltage: Load current of less than 10 mA: 1 V max., Load current of 10 to 100 mA:2 V max.).
*5. The following details apply to the input.
        
| Contact input (relay or switch) | Non-contact input (transistor) | Input time*5-1 | |
|---|---|---|---|
| NPN | ON: Shorted to 0 V
 (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc.  | 
									ON: 1.5 V max. (Sourcing current: 1 mA max.)
 OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)  | 
									ON: 9 ms min.
 OFF: 20 ms min.  | 
								
| PNP | ON: Shorted to Vcc
 (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V.  | 
									ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA max.)
 OFF: 1.5 V max. (Leakage current: 0.1 mA max.)  | 
								
            *5-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.
*6. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
*7. When connected to an OMRON NJ-series Controller.
*8. The bank is not reset by the user reset function or saved by the user save function.
*9. Eco LO is supported for Amplifier Units manufactured in July 2014 or later.
						
* When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
        
| Model | E39-R21 | E39-R22 | E39-RS10 | E39-RS11 | 
|---|---|---|---|---|
| Ambient temperature | Operating: -10 to 55°C; Storage: -25 to 70°C (with no icing or condensation) | |||
| Ambient humidity | Operating/storage: 35% to 85% (with no condensation) | |||
| Vibration resistance
 (destruction)  | 
									10 to 55 Hz with a 1.5-mm double amplitude or 100 m/s2 for 2 hours each in X, Y, and Z directions | |||
| Shock resistance
 (destruction)  | 
									500 m/s2 3 times each in X, Y, and Z directions | |||
| Degree of protection | IEC IP67 (E39-R21 and E39-R22 only) | |||
| Materials | Reflective surface: Methacrylic resin (PMMA)
 Back surface: Polybutylene terephthalate (PBT)  | 
									Methacrylic resin (PMMA) | ||
| Weight
 (packed state/ Reflector only)  | 
									Approx. 30 g/
 approx. 5 g  | 
									Approx. 35 g/
 approx. 10 g  | 
									Approx. 35 g/
 approx. 10 g  | 
									Approx. 30 g/
 approx. 5 g  | 
								
| Accessories | Instruction manual | |||
| Sensing method | Distance-settable | |||
|---|---|---|---|---|
| Model | E3NC-SH250H | E3NC-SH250 | E3NC-SH100 | |
| Light source
 (wavelength)  | 
Visible semiconductor laser
 diode (660 nm), 1.2 mW max.  | 
Visible semiconductor laser diode (660 nm), 0.54 mW max. | ||
| Laser class | Class 1 (JIS, IEC/EN, FDA *1, GB/T) | |||
| Measurement range | 35 to 250 mm (display value: 350 to 2,500) | 35 to 100 mm (display value:
 350 to 1,000)  | 
||
| Standard detected level
 difference *2  | 
35 to 180mm: 9 mm
 180 to 250 mm: 25 mm  | 
35 to 50 mm: 1.5 mm
 50 to 100 mm: 3 mm  | 
||
| Beam size*3 | Approx. 1 mm dia. at 250 mm | Approx. 0.5 mm dia. at 100 mm | ||
| Indicators | OUT indicator (orange), STABILITY indicator (green), and ST indicator (blue) | |||
| Ambient illumination
 (Receiver side)  | 
Incandescent lamp: 4,000 lx
 max., Sunlight: 8,000 lx max.  | 
Incandescent lamp: 2,000 lx
 max., Sunlight: 4,000 lx max.  | 
Incandescent lamp: 4,000 lx
 max., Sunlight: 8,000 lx max.  | 
|
| Ambient temperature
 range  | 
Operating: -10 to 50°C; Storage: -25 to 70°C (with no icing or condensation) | |||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | |||
| Altitude | 2,000 m max. | |||
| Installation environment | Pollution degree 3 (as per IEC 60947-1) | |||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
| Vibration resistance
 (destruction)  | 
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
| Shock resistance
 (destruction)  | 
500 m/s2 3 times each in X, Y, and Z directions | |||
| Degree of protection | IEC IP67 | |||
| Connecting method | Pre-wired connector (Standard cable length: 2 m) | |||
| Materials | Case | Polybutylene terephthalate (PBT) | ||
| Lens | Methacrylic resin (PMMA) | |||
| Cable | Vinyl chloride (PVC) | |||
| Weight (packed state/
 Sensor Head only)  | 
Approx. 125 g/approx. 75 g | |||
| Accessories | Instruction Manual, laser warning label (E3NC-SH250H only) | |||
            Note: Incorrect detection may occur outside the measurement range if the object has a high reflection factor.
*1. These Sensors are classified as Class 1 laser devices under IEC 60825-1: 2014 and the regulations of Laser Notice
      No. 56 for FDA certification.
      CDRH (Center for Devices and Radiological Health) registration has been completed. (Accession Number: 1220691-002)
*2. The values were measured at the center of the sensing distance using OMRON’s standard sensing object
      (white ceramic).
*3. Beam size: Defined at the 1/e2 (13.5 %) of the central intensity at the measurement center distance.
      Measurement may be influenced if there is light leakage outside the defined region and the surroundings of the target
      object have a high reflectance in comparison to the target object.
      Also, when detecting a workpiece that is smaller than the beam size, a correct value may not be obtained.
        
| Type | Standard models | Model for Sensor
 Communications Unit  | 
								|||
|---|---|---|---|---|---|
| NPN output | E3NC-SA21 | E3NC-SA7 | E3NC-SA24 | E3NC-SA0 | |
| PNP output | E3NC-SA51 | E3NC-SA9 | E3NC-SA54 | ||
| Connecting method | Pre-wired | Wire-saving
 Connector  | 
									M8
 Connector  | 
									Connector for Sensor
 Communications Unit  | 
								|
| Inputs/
 outputs  | 
									Outputs | 2 outputs | 1 output | --- *1 | |
| External inputs | 1 input | ||||
| Power supply voltage *2 | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the
 connector through the Sensor Communications Unit  | 
								|||
| Power consumption *3 | At Power Supply Voltage of 24 VDC
 Normal mode: 1,920 mW max. (Current consumption: 80 mA max.) Eco ON: 1,680 mW max. (Current consumption: 70 mA max.) Eco LO: 1,800 mW max. (Current consumption: 75 mA max.)  | 
								||||
| Control outputs *4 | Load power supply voltage: 30 VDC max.,
 open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max.  | 
									―― | |||
| External inputs | Refer to *5. | ||||
| Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
 Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), ZERO indicator (green), and OUT selection indicator (orange, only on models with 2 outputs)  | 
								||||
| Protection circuits | Power supply reverse polarity protection,
 output short-circuit protection, and output reverse polarity protection  | 
									Power supply reverse
 polarity protection and output short-circuit protection  | 
								|||
| Response
 time  | 
									Super-high-speed mode (SHS) *6 | Operate or reset: 1.5 ms | |||
| High-speed mode (HS) | Operate or reset: 5 ms | ||||
| Standard mode (Stnd) | Operate or reset: 10 ms | ||||
| Giga-power mode (GIGA) | Operate or reset: 50 ms | ||||
| Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, 1-point tuning, tuning without workpiece,
 2-point area tuning, 1-point area tuning, or area tuning without workpiece), or manual adjustment  | 
								||||
| Maximum connectable Units | 30 | With E3NW-ECT: 30 units *7
 With E3NW-CRT: 16 units With E3NW-CCL: 16 units  | 
								|||
| No. of Units
 for mutual interference prevention  | 
									Super-high-speed mode (SHS) *6 | 0 | |||
| High-speed mode (HS) | 2 | ||||
| Standard mode (Stnd) | 2 | ||||
| Giga-power mode (GIGA) | 2 | ||||
| Functions | Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
 + OFF-delay timer: 1 to 9,999 ms  | 
								|||
| Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
| Resetting settings *8 | Select from initial reset (factory defaults) or user reset (saved settings). | ||||
| Eco mode *9 | Select from OFF (digital display lit), ECO ON (digital display not lit), and ECO LO (digital display dimmed). | ||||
| Bank switching | Select from banks 1 to 4. | ||||
| Output 1 | Select from Normal detection mode, Area detection mode, or hold mode. | ||||
| Output 2 | Select from
 Normal detection mode or Error output mode.  | 
									--- | Select from Normal
 detection mode or Error output mode.  | 
								||
| External input | Select from input OFF, tuning, laser OFF,
 zero reset, or bank switching.  | 
									―― | |||
| Keep function *10 | Select from ON or OFF. | ||||
| Background suppression *11 | Select from ON or OFF. | ||||
| Hysteresis width | Select from standard setting or user setting. | ||||
| Ambient temperature range* | Operating:
 Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation)  | 
									Operating:
 Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation)  | 
								|||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Insulation resistance | 20 MΩ (at 500 VDC) | ||||
| Altitude | 2,000 m max. | ||||
| Installation environment | Pollution degree 3 (as per IEC 60947-1) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
| Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each
 in X, Y, and Z directions  | 
								|||
| Weight (packed state/Amplifier Unit only) | Approx. 115 g/
 approx. 75 g  | 
									Approx. 60 g/
 approx. 20 g  | 
									Approx. 65 g/approx. 25 g | ||
| Materials | Case | Polycarbonate (PC) | |||
| Cover | Polycarbonate (PC) | ||||
| Cable | Vinyl chloride (PVC) | ||||
| Accessories | Instruction Manual | ||||
            *1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
      PLC operation via Communications Unit enables reading detected values and changing settings.
*2. Applicable Sensor Head is the series of E3NC-SH[][].
*3. At Power Supply Voltage of 10 to 30 VDC.
      Normal mode: 2,250 mW max. (Current consumption: 75 mA max. at 30 VDC, 145 mA max. at 10 VDC)
      Eco ON: 2,010 mW max. (Current consumption: 67 mA max. at 30 VDC, 125 mA max. at 10 VDC)
      Eco LO: 2,130 mW max. (Current consumption: 71 mA max. at 30 VDC, 135 mA max. at 10 VDC)
*4. The total for both outputs of a model with 2 outputs is 100 mA max.
      (Residual voltage: Load current of less than 10 mA: 1 V max., Load current of 10 to 100 mA: 2 V max.).
*5. The following details apply to the input.
        
| Contact input (relay or switch) | Non-contact input (transistor) | Input time*5-1 | |
|---|---|---|---|
| NPN | ON: Shorted to 0 V
 (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc.  | 
									ON: 1.5 V max. (Sourcing current: 1 mA max.)
 OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.)  | 
									ON: 9 ms min.
 OFF: 20 ms min.  | 
								
| PNP | ON: Shorted to Vcc
 (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V.  | 
									ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA max.)
 OFF: 1.5 V max. (Leakage current: 0.1 mA max.)  | 
								
            *5-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) input is selected.
*6. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.
*7. When connected to an OMRON NJ-series Controller.
*8. The bank is not reset by the user reset function or saved by the user save function.
*9. Eco LO is supported for Amplifier Units manufactured in August 2014 or later.
*10. The output for a measurement error is set.
      ON: The value of the output from before the measurement error is retained.
      OFF: The output is turned OFF when a measurement error occurs.
*11. Only the sensing object is detected when tuning.
						
* When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
        
last update: May 26, 2025