Smart Camera
last update: November 1, 2024
Item | Single-
function type |
Standard
type |
High-resolution type | ||||
---|---|---|---|---|---|---|---|
Model | NPN | FQ2-
S10[][][][] |
FQ2-
S20[][][][] |
FQ2-
S30[][][][] -08 |
FQ2-
S30[][][][] -08M |
FQ2-
S30-13 |
FQ2-
S30-13M |
PNP | FQ2-
S15[][][][] |
FQ2-
S25[][][][] |
FQ2-
S35[][][][] -08 |
FQ2-
S35[][][][] -08M |
FQ2-
S35-13 |
FQ2-
S35-13M |
|
Field of view | Refer to Ordering Information on Lineup.
(Tolerance (field of view): ± 10% max.) |
Select a lens according
to the field of view and installation distance. Refer to the optical chart on Catalog. |
|||||
Installation distance | |||||||
Main
functions |
Inspection
items |
Shape Search III, Shape Search II, Search, sensitive search, area, color data, edge
position, edge pitch, edge width, and labeling |
|||||
Number of
simultaneous measurements |
1 | 32 | |||||
Position
compensation |
Supported (360º Model position compensation, Edge position compensation) | ||||||
Number of
registered scenes |
8 * | 32 * | |||||
Calibration | Supported | ||||||
Image
input |
Image
processing method |
Real color | Monochrome | Real color | Monochrome | ||
Image filter | High dynamic range (HDR), image adjustment (Color Gray Filter, Weak smoothing,
Strong smoothing, Dilate, Erosion, Median, Extract edges, Extract horizontal edges, Extract vertical edges, Enhance edges, Background suppression), polarizing filter (attachment), and white balance (Sensors with Color Cameras only), Brightness Correction |
||||||
Image
elements |
1/3-inch color CMOS | 1/2-inch
color CMOS |
1/2-inch
Monochrome CMOS |
1/2-inch
color CMOS |
1/2-inch
Monochrome CMOS |
||
Shutter | Built-in lighting ON:
1/250 to 1/50,000s Built-in lighting OFF: 1/1 to 1/50,000s |
Built-in lighting ON:
1/250 to 1/60,000s Built-in lighting OFF: 1/20 to 1/4,155s |
Built-in lighting ON:
1/250 to 1/60,000s Built-in lighting OFF: 1/1 to 1/4,155s |
1/20 to
1/4,155s |
1/1 to
1/4,155s |
||
Processing
resolution |
752 × 480 | 928 × 828 | 1280 × 1024 | ||||
Partial input
function |
Supported horizontally
only. |
Supported horizontally and vertically | |||||
Image display | Zoom-in/Zoom-out/Fit, Rotating by 180° | ||||||
Lens mounts | --- | C-mount | |||||
Lighting | Lighting method | Pulse | --- | ||||
Lighting color | White | --- | |||||
Data
logging |
Measurement
data |
In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the
capacity of an SD card.) |
|||||
Images | In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the
capacity of an SD card.) |
||||||
Auxiliary function | Statistical data, Test Measurements, I/O monitor, Password function, Simulation
software, Sensor error history, Calibration, Math (arithmetic, calculation functions, trigonometric functions, and logic functions) |
||||||
Measurement trigger | External trigger (single or continuous)
Communications trigger (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link , or PROFINET) |
||||||
I/O
specifi- cations |
Input signals | 7 signals
Single measurement input (TRIG) Control command input (IN0 to IN5) |
|||||
Output signals | 3 signals
• Control output (BUSY) • Overall judgement output (OR) • Error output (ERROR) Note: The assignments of the three output signals (OUT0 to OUT2) can also be changed to the following: • READY • RUN • STG (Strobe trigger) • OR0 (Item0 judgement) to OR31 (Item31 judgement) • Exp.0 judgement to Exp.31 judgement |
||||||
Ethernet
specifications |
100Base-TX/10Base-T | ||||||
Communications | Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol,
EtherNet/IP, PLC Link , or PROFINET |
||||||
I/O expansion | --- | --- | Possible by connecting FQ-SDU1_ Sensor Data Unit. 11
inputs and 24 outputs |
||||
RS-232C | --- | --- | Possible by connecting FQ-SDU2_ Sensor Data Unit. 8
inputs and 7 outputs |
||||
Ratings | Power supply
voltage |
21.6 to 26.4 VDC (including ripple) | |||||
Current
consumption |
2.4 A max. | 0.3 A max. | |||||
Environ-
mental immunity |
Ambient
temperature range |
Operating: 0 to 50ºC
Storage: -25 to 65ºC (with no icing or condensation) |
Operating: 0 to 40ºC
Storage: -25 to 65ºC (with no icing or condensation) |
||||
Ambient
humidity range |
Operating and storage: 35% to 85% (with no condensation) | ||||||
Ambient
atmosphere |
No corrosive gas | ||||||
Vibration
resistance (destruction) |
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times |
||||||
Shock
resistance (destruction) |
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward) | ||||||
Degree of
protection |
IEC 60529 IP67 (Except when Polarizing Filter
Attachment is mounted or connector cap is removed.) |
IEC 60529 IP40 | |||||
Materials | Sensor: PBT, PC, SUS
Mounting Bracket: PBT Polarizing Filter Attachment: PBT, PC Ethernet connector: Oil-resistance vinyl compound I/O connector: Lead-free heat-resistant PVC |
Cover: Zinc-plated
steel, Thickness: 0.6 mm Case: Aluminum diecast alloy (ADC-12) Mounting base: Polycarbonate ABS |
|||||
Weight | Narrow View/Standard View:Approx.160 g
Wide View:Approx.150 g |
Approx. 160 g
without base, Approx. 185 g with base |
|||||
Accessories
included with sensor |
Mounting Bracket (FQ-XL) (1)
Polarizing Filter Attachment (FQ-XF1) (1) Instruction Manual, Member Registration Sheet |
Mounting Base
(FQ-XLC) (1) Mounting Screw (M3 × 8 mm) (4) Instruction Manual, Member Registration Sheet |
|||||
LED class | Risk Group 2 (IEC62471) | --- |
* The maximum number of registerable scenes depends on settings due to restrictions on memory.
Item | Inspection/ID Model | ||||||
---|---|---|---|---|---|---|---|
Model | NPN | FQ2-
S40[][][][] |
FQ2-
S40[][][][] -M |
FQ2-
S40[][][][] -08 |
FQ2-
S40[][][][] -08M |
FQ2-
S40[][][][] -13 |
FQ2-
S40[][][][] -13M |
PNP | FQ2-
S45[][][][] |
FQ2-
S45[][][][] -M |
FQ2-
S45[][][][] -08 |
FQ2-
S45[][][][] -08M |
FQ2-
S45[][][][] -13 |
FQ2-
S45[][][][] -13M |
|
Field of view | Refer to Ordering Information on Lineup.
(Tolerance (field of view): ± 10% max.) |
Select a lens according
to the field of view and installation distance. Refer to the optical chart on Catalog. |
|||||
Installation distance | |||||||
Main
functions |
Inspection
items |
Shape Search III, Shape Search II, Search, Sensitive Search, Area, Color Data, Edge
Position, Edge Pitch, Edge Width, Labeling, OCR *1, Bar code *2, 2D-code *2, 2D-code (DMP) *3, and Model Dictionary |
|||||
Number of
simultaneous measurements |
32 | ||||||
Position
compensation |
Supported (360º Model position compensation, Edge position compensation, Linear
correction) |
||||||
Number of
registered scenes |
32 *4 | ||||||
Calibration | Supported | ||||||
Retry function | Normal retry, Exposure retry, Scene retry, Trigger retry | ||||||
Print Quality
Grading Function |
Applicable standards: ISO/IEC TR 29158 (AIM DPM-1-2006)
(Applicable code: Data Matrix ECC200) |
||||||
Image
input |
Image
processing method |
Real color | Monochrom | Real color | Monochrome | Real color | Monochrome |
Image filter | High dynamic range (HDR), image adjustment (Color Gray Filter, Weak smoothing,
Strong smoothing, Dilate, Erosion, Median, Extract edges, Extract horizontal edges, Extract vertical edges, Enhance edges, Background suppression), polarizing filter (attachment), and white balance (Sensors with Color Cameras only), Brightness Correction |
||||||
Image
elements |
1/3-inch color CMOS | 1/3-inch
Monochrome CMOS |
1/2-inch
Monochrome CMOS |
1/2-inch
color CMOS |
1/2-inch
Monochrome CMOS |
||
Shutter | Built-in lighting ON:
1/250 to 1/50,000s Built-in lighting OFF: 1/1 to 1/50,000s |
Built-in lighting ON:
1/250 to 1/60,000s Built-in lighting OFF: 1/20 to 1/4,155s |
Built-in lighting ON:
1/250 to 1/60,000s Built-in lighting OFF: 1/1 to 1/4,155s |
1/20 to
1/4,155s |
1/1 to
1/4,155s |
||
Processing
resolution |
752 × 480 | 928 × 828 | 1280 × 1024 | ||||
Partial input
function |
Supported horizontally
only. |
Supported horizontally and vertically | |||||
Image display | Zoom-in/Zoom-out/Fit, Rotating by 180° | ||||||
Lens mounts | --- | C-mount | |||||
Lighting | Lighting method | Pulse | --- | ||||
Lighting color | White | --- | |||||
Data
logging |
Measurement
data |
In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the
capacity of an SD card.) |
|||||
Images | In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the
capacity of an SD card.) |
||||||
Auxiliary function | Statistical data, Test Measurements, I/O monitor, Password function, Simulation
software, Sensor error history, Calibration, Math (arithmetic, calculation functions, trigonometric functions, and logic functions) |
||||||
Measurement trigger | External trigger (single or continuous)
Communications trigger (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol, EtherNet/IP, PLC Link , or PROFINET) |
||||||
I/O
specifi- cations |
Input signals | 7 signals
Single measurement input (TRIG) Control command input (IN0 to IN5) |
|||||
Output signals | 3 signals
• Control output (BUSY) • Overall judgement output (OR) • Error output (ERROR) Note: The assignments of the three output signals (OUT0 to OUT2) can also be changed to the following: • READY • RUN • STG (Strobe trigger) • OR0 (Item0 judgement) to OR31 (Item31 judgement) • Exp.0 judgement to Exp.31 judgement |
||||||
Ethernet
specifications |
100Base-TX/10Base-T | ||||||
Communications | Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP no-protocol,
EtherNet/IP, PLC Link , or PROFINET |
||||||
I/O expansion | Possible by connecting FQ-SDU1_ Sensor Data Unit. 11 inputs and 24 outputs | ||||||
RS-232C | Possible by connecting FQ-SDU2_ Sensor Data Unit. 8 inputs and 7 outputs | ||||||
Ratings | Power supply
voltage |
21.6 to 26.4 VDC (including ripple) | |||||
Current
consumption |
2.4 A max. | 0.3 A max. | |||||
Environ-
mental immunity |
Ambient
temperature range |
Operating: 0 to 40ºC
Storage: -25 to 65ºC (with no icing or condensation) |
|||||
Ambient
humidity range |
Operating and storage: 35% to 85% (with no condensation) | ||||||
Ambient
atmosphere |
No corrosive gas | ||||||
Vibration
resistance (destruction) |
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times |
||||||
Shock
resistance (destruction) |
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward) | ||||||
Degree of
protection |
IEC 60529 IP67 (Except when Polarizing Filter
Attachment is mounted or connector cap is removed.) |
IEC 60529 IP40 | |||||
Materials | Sensor: PBT, PC, SUS
Mounting Bracket: PBT Polarizing Filter Attachment: PBT, PC Ethernet connector: Oil-resistance vinyl compound I/O connector: Lead-free heat-resistant PVC |
Cover: Zinc-plated
steel, Thickness: 0.6 mm Case: Aluminum diecast alloy (ADC-12) Mounting base: Polycarbonate ABS |
|||||
Weight | Narrow View/Standard View:Approx.160 g
Wide View:Approx.150 g |
Approx. 160 g without base,
Approx. 185 g with base |
|||||
Accessories
included with sensor |
Mounting Bracket (FQ-XL) (1)
Polarizing Filter Attachment (FQ-XF1) (1) Instruction Manual, Member Registration Sheet |
Mounting Base
(FQ-XLC) (1) Mounting Screw (M3 × 8 mm) (4) Instruction Manual, Member Registration Sheet |
|||||
LED class | Risk Group 2 (IEC62471) | --- |
Item | Optical Character
Recognition Sensor |
Multi Code Reader | 2D Code Reader | |
---|---|---|---|---|
Model | NPN | FQ2-CH10[][][][]-M | FQ-CR10[][][][]-M | FQ-CR20[][][][]-M |
PNP | FQ2-CH15[][][][]-M | FQ-CR15[][][][]-M | FQ-CR25[][][][]-M | |
Field of view | Refer to Ordering Information on Lineup. (Tolerance (field of view): ± 10% max.) | |||
Installation distance | ||||
Main
functions |
Inspection
items |
OCR
Alphabet A to Z Number 0 to 9 Symbol ' - .: / Model dictionary |
2D Code (Data Matrix
(ECC200), QR Code, MicroQR Code, PDF417, MicroPDF417, GS1- DataMatrix) |
2D Code
(Data Matrix (ECC200), QR Code) |
Bar Code (JAN/EAN/UPC,
Code39, Codabar (NW-7), ITF (Interleaved 2 of 5), Code 93, Code128/GS1- 128, GS1 DataBar* (Truncated, Stacked, Omni-directional, Stacked Omnidirectional, Limited, Expanded, Expanded Stacked), Pharmacode, GS1-128 Composite Code (CC-A, CC-B, CC-C)) |
||||
Image filter | Weak smoothing, Strong
smoothing, Dilate, Erosion, Median, Extract edges, Extract horizontal edges, Extract vertical edges, Enhance edges, Background suppression |
None | Filter function
(Smooth, Dilate, Erosion, Median), Code Error Correction Position Display |
|
Verification
function |
Supported | Supported | None | |
Retry function | Normal retry, Exposure retry,
Scene retry, Trigger retry |
None | Normal retry,
Exposure retry, Scene retry, Trigger retry |
|
Number of
simultaneous measurements |
32 | |||
Position
compensation |
Supported (360º Model position compensation, Edge
position compensation, Linear correction) |
None | ||
Number of
registered scenes |
32 | |||
Image
input |
Image processing
method |
Monochrome | ||
Image filter | High dynamic range (HDR),
polarizing filter (attachment), Brightness Correction |
High dynamic range (HDR), polarizing filter
(attachment) |
||
Image elements | 1/3-inch Monochrome CMOS | |||
Shutter | Built-in lighting ON:
1/250 to 1/50,000s Built-in lighting OFF: 1/1 to 1/50,000s |
1/250 to 1/30,000s | 1/250 to 1/32,258s | |
Processing
resolution |
752 × 480 | |||
Partial input
function |
Supported horizontally only. | |||
Image display | Zoom-in/Zoom-out/Fit,
Rotating by 180° |
Zoom-in/Zoom-out/Fit | ||
Lighting | Lighting method | Pulse | ||
Lighting color | White | |||
Data
logging |
Measurement
data |
In Sensor: 1,000 items (If a Touch Finder is used, results can be saved up to the
capacity of an SD card.) |
||
Images | In Sensor: 20 images (If a Touch Finder is used, images can be saved up to the
capacity of an SD card.) |
|||
Auxiliary function | Statistical data, Test Measurements, I/O monitor, Password function, Simulation
software, Sensor error history, Calibration |
|||
Math function | Arithmetic, calculation functions, trigonometric functions,
and logic functions |
--- | ||
Measurement trigger | External trigger (single or
continuous) Communications trigger (Ethernet TCP no-protocol, Ethernet UDP no-protocol, Ethernet FINS/TCP noprotocol, EtherNet/IP, PLC Link, or PROFINET) |
External trigger (single or continuous)
Communications trigger (Ethernet TCP no-protocol) |
||
I/O
specifi- cations |
Input signals | 7 signals
Single measurement input (TRIG) Control command input (IN0 to IN5) |
||
Output signals | 3 signals
• Control output (BUSY) • Overall judgement output (OR) • Error output (ERROR) Note: The assignments of the three output signals (OUT0 to OUT2) can also be changed to the following: • READY • RUN • STG (Strobe trigger) • OR0 (Item0 judgement) to OR31 (Item31 judgement) • Exp.0 judgement to Exp.31 judgement |
3 signals
• Control output (BUSY) • Overall judgement output (OR) • Error output (ERROR) Note: Note:The three output signals can be allocated for the judgements of individual inspection items. |
||
Ethernet
specifications |
100Base-TX/10Base-T | |||
Communications | Ethernet TCP no-protocol,
Ethernet UDP no-protocol, Ethernet FINS/TCP no- protocol, EtherNet/IP, PLC Link, or PROFINET |
Ethernet TCP no-protocol | ||
I/O expansion | Possible by connecting FQ-
SDU1_ Sensor Data Unit. 11 inputs and 24 outputs |
--- | ||
RS-232C | Possible by connecting
FQ-SDU2_ Sensor Data Unit. 8 inputs and 7 outputs |
--- | ||
Ratings | Power supply
voltage |
21.6 to 26.4 VDC (including ripple) | ||
Current
consumption |
2.4 A max. | |||
Environ-
mental immunity |
Ambient
temperature range |
Operating: 0 to 40ºC,
Storage: -25 to 65ºC (with no icing or condensation) |
Operating: 0 to 50ºC, Storage: -25 to 65ºC
(with no icing or condensation) |
|
Ambient
humidity range |
Operating and storage: 35% to 85% (with no condensation) | |||
Ambient
atmosphere |
No corrosive gas | |||
Vibration
resistance (destruction) |
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times |
|||
Shock resistance
(destruction) |
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward) | |||
Degree of
protection |
IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted or connector
cap is removed.) |
|||
Materials | Sensor: PBT, PC, SUS, Mounting Bracket: PBT, Polarizing Filter Attachment: PBT,
PC Ethernet connector: Oil-resistance vinyl compound, I/O connector: Lead-free heat-resistant PVC |
|||
Weight | Narrow View/Standard View: Approx.160 g Wide View: Approx.150 g | |||
Accessories included with
sensor |
Mounting Bracket (FQ-XL) (1), Polarizing Filter Attachment (FQ-XF1) (1), Instruction
Manual, Member Registration Sheet |
|||
LED class | Risk Group 2 (IEC62471) |
Type | Model with DC power supply | ||
---|---|---|---|
Model | FQ2-D30 | ||
Number of connectable Sensor | Number of sensors that can be recognized (switched): 32 max. number
or sensor that can displayed on monitor: 8 max. |
||
Main
functions |
Types of measurement
displays |
Last result display, Last NG display, trend monitor, histograms | |
Types of display images | Through, frozen, zoom-in, and zoom-out images | ||
Data logging | Measurement results, measured images | ||
Menu language | English, German, French, Italian, Spanish, Traditional Chinese, Simplified
Chinese, Korean, Japanese |
||
Indications | LCD | Display device | 3.5-inch TFT color LCD |
Pixels | 320 × 240 | ||
Display colors | 16.7 million | ||
Backlight | Life expectancy
*1 |
50,000 hours at 25ºC | |
Brightness
adjustment |
Provided | ||
Screen saver | Provided | ||
Operation
interface |
Touch
screen |
Method | Resistance film |
Life expectancy
*2 |
1,000,000 touch operations | ||
External
interface |
Ethernet | 100BASE-TX/10BASE-T | |
SD card | SDHC-compliant, Class 4 or higher recommended | ||
Ratings | Power supply voltage | DC power connection:21.6 to 26.4 VDC
(including ripple) |
|
Continuous operation on
Battery *3 |
--- | ||
Power consumption | DC power connection: 0.2 A max. | ||
Environ-
mental immunity |
Ambient temperature
range |
Operating: 0 to 50ºC
Storage: - 25 to 65ºC (with no icing or condensation) |
|
Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||
Ambient atmosphere | No corrosive gas | ||
Vibration resistance
(destruction) |
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times |
||
Shock resistance
(destruction) |
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and
backward) |
||
Degree of protection | IEC 60529 IP20 (when SD card cover, connector cap, or harness is
attached) |
||
Weight | Approx. 270 g (without Battery and hand strap attached) | ||
Materials | Case: ABS | ||
Accessories included with Touch
Finder |
Touch Pen (FQ-XT), Instruction Manual |
Item | Parallel Interface | RS-232C Interface | ||
---|---|---|---|---|
Model | NPN | FQ-SDU10 | FQ-SDU20 | |
PNP | FQ-SDU15 | FQ-SDU25 | ||
I/O
specifi- cations |
Parallel
I/O |
Connector 1 | 16 outputs (D0 to D15) | 6 inputs (IN0 to IN5) |
Connector 2 | 11 inputs (TRIG, RESET, IN0 to IN7,
and DSA) 8 outputs (GATE, ACK, RUN, BUSY, OR, ERROR, STGOUT, and SHTOUT) |
2 inputs (TRIG and RESET)
7 outputs (ACK, RUN, BUSY, OR, ERROR, STGOUT, and SHTOUT) |
||
RS-232C | --- | 1 channel, 115,200 bps max. | ||
Sensor interface | FQ2-S3 connected with FQ-WU[][][]: OMRON interface
*Number of connected Sensors: 1 |
|||
Ratings | Power supply voltage | 21.6 to 26.4 VDC (including ripple) | ||
Insulation resistance | Between all DC external terminals and case: 0.5 MΩ min (at 250 VDC) | |||
Current consumption | 2.5 A max.: FQ2-S[][][][][][]-[][][] and FQ-SDU[][], FQ2-CH1[][][][][]-M and
FQ-SDU[][] 0.4 A max.: FQ2-S[][]-[][][] and FQ-SDU[][] 0.1 A max.: FQ-SDU[][] only |
|||
Environ-
mental immunity |
Ambient temperature
range |
Operating: 0 to 50ºC, Storage: -20 to 65ºC (with no icing or condensation) | ||
Ambient humidity
range |
Operating and storage: 35% to 85% (with no condensation) | |||
Ambient atmosphere | No corrosive gas | |||
Vibration resistance
(destruction) |
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions, 8 min each, 10 times | |||
Shock resistance
(destruction) |
150 m/s2 3 times each in 6 directions (up, down, right, left, forward, and
backward) |
|||
Degree of protection | IEC 60529 IP20 | |||
Materials | Case: PC + ABS, PC | |||
Weight | Approx. 150 g | |||
Accessories included with
Sensor Data Unit |
Instruction Manual |
The following Personal Computer system is required to use the software.
OS | Microsoft Windows 7 Home Premium or higher (32-bit/64-bit version)
Microsoft Windows 8.1 Pro Edition or higher (32-bit/64-bit version) Microsoft Windows 10 Home Edition or higher (32-bit/64-bit version) Microsoft Windows 11 Pro Edition (64-bit version) |
---|---|
CPU | Core 2 Duo 1.06 GHz or the equivalent or higher |
RAM | 1GB min. |
HDD | 500 MB min. available space * |
Monitor | 1,024 × 768 dots min. |
* Available space is also required separately for data logging.
last update: November 1, 2024