J7KCA Series

Auxiliary Relay (Contactor Relay)

J7KCA Series

Same shape as J7KC magnetic contactors Ideal for standardizing panel design

Coil rating

AC operated

Displayed
model
Rated voltage Allowable voltage range Must operate
voltage
Must release
voltage
50 Hz 60 Hz 50 Hz 60 Hz
AC 24 24 VAC 24-26 VAC 85 to 110% 21-27 VAC 21-29 VAC 85% max. 20% min.
AC 48 48 VAC 48-52 VAC 41-53 VAC 41-58 VAC
AC 100 100 VAC 100-110 VAC 85-110 VAC 85-121 VAC
AC 110 100-110 VAC 110-120 VAC 85-121 VAC 94-132 VAC
AC 120 110-120 VAC 120-130 VAC 94-132 VAC 102-143 VAC
AC 200 200 VAC 200-220 VAC 170-220 VAC 170-242 VAC
AC 220 200-220 VAC 220-240 VAC 170-242 VAC 187-264 VAC
AC 230 220-230 VAC 230 VAC 187-253 VAC 196-253 VAC
AC 240 220-240 VAC 240-260 VAC 187-264 VAC 204-286 VAC
AC 380 346-380 VAC 380-420 VAC 295-418 VAC 323-462 VAC
AC 400 380-400 VAC 400-440 VAC 323-440 VAC 340-484 VAC
AC 440 415-440 VAC 440-480 VAC 353-484 VAC 374-528 VAC
AC 500 480-500 VAC 500-550 VAC 408-550 VAC 425-605 VAC

DC operated

Displayed
model
Rated voltage Allowable voltage range Must operate
voltage
Must release
voltage
DC 12 12 VDC 85 to 110% 11-14 VDC 85% max. 10% min.
DC 24 24 VDC 21-27 VDC
DC 48 48 VDC 41-53 VDC
DC 60 60 VDC 51-66 VDC
DC 100 100 VDC 85-110 VDC
DC 110 110 VDC 94-121 VDC
DC 120 120 VDC 102-132 VDC
DC 200 200 VDC 170-220 VDC
DC 210 210 VDC 179-231 VDC
DC 220 220 VDC 187-242 VDC

Coil characteristics (reference value)

AC operated

Frequency 50 Hz 60 Hz
Coil power consumption Making (VA) 22 (200 V) 25 (220 V)
Holding (VA) 4.5 (200 V) 4.5 (220 V)
Power loss (W) 1.2 (200 V) 1.3 (220 V)
Must operate voltage (V) 122 to 135 128 to 138
Must release voltage (V) 80 to 89 83 to 96
Operate time (ms) 17 to 26
Release time (ms) 6 to 16

Note:
1. Coil ratings: Characteristics for 200 VAC, 50 Hz / 200-220 VAC, 60 Hz
2. Coil power consumption value is the same for a coil that is not rated 200 VAC.
3. Indicated operate/release times for 200 VAC, 50 Hz.
4. Closed and open voltages of 100 V coil (100 VAC, 50 Hz/100-110 VAC, 60 Hz) are approximately one half the values in the table above.
5. Values in the table above are examples for 20°C cold condition.

DC operated

Coil power consumption Making (W) 2.4 (24 V)
Holding (W) 2.4 (24 V)
Time constant (ms) Holding 20
Must operate voltage (V) 10 to 11
Must release voltage (V) 4 to 6
Operate time (ms) 34 to 60
Release time (ms) 5 to 10

Note:
1. Coil ratings: Characteristics for 24 VDC
2. Coil power consumption value is the same for a coil that is not rated 24 VDC.
3. Values in the table above are examples for 20°C cold condition.

Characteristics

Auxiliary
circuit
ratings
Ratings
based on
IEC
60947-5-1/
JIS C
8201-5-1
Voltage
range (V)
100-120
AC
200-24
AC
380-440
AC
500-600
AC
24 DC 48 DC 110 DC 220 DC
Rated
operational
current (A)
AC-15 (coil load) DC-13 (coil load)
3 3 1 0.5 2 1 0.3 0.2
AC-12 (resistive load) DC-12 (resistive load)
6 6 6 3 3 2 1.5 0.5
Contact
closed and
breaking
current (A)
30 30 10 5 30 30 10 5
Conventional
free air
thermal
current
(rated carry
current) (A)
10
Ratings
based on
UL 508
Rated carry
current (A)
10 2.5
Voltage
range
120 AC 240 AC 480 AC 600 AC 125 DC 250 DC
Contact
closed
current (A)
60 30 15 12 0.55 0.27
Breaking
current (A)
6 3 1.5 1.2 0.55 0.27
Rating code A 600 Q 300
Minimum operate
voltage/current
(reference value)
5 VDC, 3 mA
Rated insulation voltage 690 VAC
Rated impulse dielectric strength 6 kV
Rated frequency 50/60 Hz
Vibration resistance Vibration: 10 to 55 Hz, acceleration: 15 m/s2
Shock resistance Shock value 50 m/s2
Electrical/
mechanical
endurance
Switching frequency
(times per hour)
1800
Mechanical
(10,000 operations min.)
1000
Electrical
(10,000
operations
min.)
AC-15 220 V 50
440 V 50
AC-12 220 V 25
440 V 25
DC-13 220 V 15
DC-12 220 V 50
Contact resistance (reference value) 50 mΩ max. (1 mA at 6 VDC using the voltage drop method)
Contact structure Double-break
Contact material Ag alloy
Linked contact Available *
Degree of protection IP20 (IEC60529)
Operating temperature -10 to +55°C (however, daily average shall not exceed 35°C)
Ambient storage temperature -40 to +65°C (no condensation or icing)
Relative humidity 45% to 85% RH (no condensation or icing)
Altitude 2000 m max.
Weight 160 g (J7KCA-[]-AC)/190 g (J7KCA-[]-DC)
Applicable
standards
Safety standard EN 60947-5-1 (IEC 60947-5-1), UL 60947-4-1,
CSA 22.2 No.60947-4-1, CCC GB/T 14048.5, UKCA

* A linked contact is a mechanism found mainly in auxiliary relays. (Applicable models: J73KCA-31, J73KCA-22)
With the combination of the auxiliary circuit of the main unit, welding the NO (or NC) contacts will result in a structure that secures a shock resistance voltage of 2.5 kV or more, or a contact interval of 0.5 mm or more, for the NC (or NO) contacts even if the excitation of the coil is released. No linked contact structure is created with the combined usage of the auxiliary contact unit (J73KC-AM).

Option (Order Separately)

Auxiliary contact unit

J73KC

Conventional
free air thermal
current
(rated flowing
current)
[A]
Contact
closed and
Breaking
current
[A]
AC DC Minimum
operate
voltage/
current
Operating
voltage
[V]
Rated operational
current [A]
Operating
voltage
[V]
Rated operational
current [A]
Coil load
(AC-15)
Resistive
load
(AC-12)
Coil load
(DC-13)
Resistive
load
(DC-12)
10 30 100 to 120 AC 3 6 24 DC 2 3 5 VDC,
3 mA
30 200 to 240 AC 3 6 48 DC 1 2
10 380 to 440 AC 1 6 110 DC 0.3 1.5
5 500 to 600 AC 0.5 3 220 DC 0.2 0.5

Coil surge absorption unit

Model Surge
absorber
Varistor
voltage
LED
indicator
Applicable model Control circuit voltage
AC operated DC operated AC DC
J76KC-RC-1 Varistor 100 V --- J7KCA-[]-AC --- 24-48 VAC Not
required
*
J76KC-RC-2 240 V 48-125 VAC
J76KC-RC-3 470 V 100-250 VAC
J76KC-RC-N-1 100 V LED (Red) 24-48 VAC
J76KC-RC-N-2 240 V 48-125 VAC

* The DC operate (J7KCA-[]-DC) has a varistor built into the main unit.