Smart Fiber Amplifier Units
last update: April 1, 2020
Type | Standard Type | Model for Sensor
Communications Unit |
||
---|---|---|---|---|
NPN output | E3NX-MA11 | E3NX-MA6 | E3NX-MA0 | |
PNP output | E3NX-MA41 | E3NX-MA8 | ||
Connecting method | Pre-wired | Wire-saving Connector | Connector for Sensor
Communications Unit |
|
Inputs/
outputs |
Outputs | 2 outputs | ---*1 | |
External inputs | --- | --- | ||
Light source (wavelength) | Red, 4-element LED (625 nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | Supplied from the connector through the Sensor Communications Unit | ||
Power consumption *2 | At Power supply voltage of 24 VDC
Normal mode: 960 mW max. (Current consumption at 40 mA max.) Eco function ON: 770 mW max. (Current consumption at 32 mA max.) Eco function LO: 870 mW max. (Current consumption at 36 mA max.) |
|||
Control output | Load power supply voltage: 30 VDC max., open-collector output
(depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
--- | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange) |
|||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | Power supply reverse polarity protection and output shortcircuit protection | ||
Response
time |
Super-high-speed mode (SHS) | Operate or reset: 100 μs | ||
High-speed mode (HS) | Operate or reset: 450 μs | |||
Standard mode (Stnd) | Operate or reset: 1ms | |||
Giga-power mode (GIGA) | Operate or reset: 16ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||
Maximum connectable Units | 30 | With E3NW-ECT: 30 units *3
With E3NW-CCL: 16 units |
||
No. of Units for mutual
interference prevention *4 |
9
Note: The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode. |
|||
Functions | Automatic power control (APC) | Always enabled. | ||
Dynamic power control (DPC) | Provided | |||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms | |||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||
Sensor OFF setting | --- | Select from ON or OFF. | ||
Bank switching | Select from banks 1 to 4. | |||
Power tuning | Select from ON or OFF. | |||
Output 1 | Select from normal detection mode or area detection mode. | |||
Output 2 | Select from normal detection mode, AND output mode, OR output mode, XOR output mode, GAP output mode, Falling synchronization mode, Rising synchronization mode or area detection mode. | |||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||
Ambient temperature range *6 | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above | |||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y, and Z directions | ||
Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | |||
Weight
(packed state/Sensor only) |
Approx. 115 g/
approx. 75 g |
Approx. 60g/
approx. 20g |
Approx. 65 g/
approx. 25 g |
|
Materials | Case | Polycarbonate (PC) | ||
Cover | Polycarbonate (PC) | |||
Cable | PVC | |||
Accessories | Instruction Manual |
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. Power consumption
At Power supply voltage of 10 to 30 VDC
Standard Models:
Normal mode : 1080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
Eco function ON: 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
*3. When connected to an OMRON NJ-series Controller.
*4. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
*5. The bank is not reset by the user reset function or saved by the user save function.
*6. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Sensing
method |
Size | Sensing
direction |
Aperture
angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||||
Through-
beam |
M4 | Right-angle | 60° | E32-T11N 2M | 1,870 | 910 | 700 | 180 |
Straight | E32-T11R 2M | 1,870 | 910 | 700 | 180 | |||
15° | E32-LT11 2M | 4,000 *1 | 3,510 | 2,700 | 700 | |||
Right-angle | E32-LT11N 2M | 4,000 *1 | 2,990 | 2,300 | 590 | |||
Straight | E32-LT11R 2M | 4,000 *1 | 2,990 | 2,300 | 590 | |||
Reflective | M3 | Right-angle | 60° | E32-C31N 2M | 100 | 44 | 32 | 9 |
E32-C21N 2M | 480 | 190 | 140 | 43 | ||||
M4 | E32-D21N 2M | 800 | 320 | 240 | 72 | |||
M6 | E32-C11N 2M | 740 | 310 | 240 | 66 | |||
15° | E32-LD11N 2M | 790 | 310 | 240 | 71 | |||
M3 | Straight | 60° | E32-D21R 2M | 130 | 57 | 40 | 11 | |
E32-C31 2M | 330 | 130 | 100 | 30 | ||||
E32-C31M 1M | 330 | 130 | 100 | 30 | ||||
M4 | E32-D211R 2M | 130 | 57 | 40 | 11 | |||
M6 | E32-D11R 2M | 800 | 320 | 240 | 72 | |||
E32-CC200 2M | 1,340 | 540 | 400 | 120 | ||||
15° | E32-LD11 2M | 820 | 330 | 250 | 74 | |||
E32-LD11R 2M | 790 | 310 | 240 | 71 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Size | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam |
1 dia. | Top-view | E32-T223R 2M | 520 | 260 | 150 | 45 |
1.5 dia. | E32-T22B 2M | 750 | 370 | 220 | 65 | ||
3 dia. | E32-T12R 2M | 1,870 | 910 | 700 | 180 | ||
Side-view | E32-T14LR 2M | 690 | 330 | 260 | 67 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 130 | 57 | 40 | 11 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 29 | 12 | 8 | 2 | ||
3 dia. | E32-D22R 2M | 130 | 57 | 40 | 11 | ||
E32-D221B 2M | 310 | 120 | 90 | 26 | |||
E32-D32L 2M | 680 | 280 | 200 | 58 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 68 | 28 | 20 | 5 |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
|||
Through-
beam |
Top-view | E32-T15XR 2M | 1,870 | 910 | 700 | 180 |
Side-view | E32-T15YR 2M | 690 | 330 | 260 | 67 | |
Flat-view | E32-T15ZR 2M | 690 | 330 | 260 | 67 | |
Reflective | Top-view | E32-D15XR 2M | 800 | 320 | 240 | 72 |
Side-view | E32-D15YR 2M | 180 | 76 | 52 | 16 | |
Flat-view | E32-D15ZR 2M | 180 | 76 | 52 | 16 |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
|||
Through-
beam |
Side-view | E32-T24R 2M | 140 | 71 | 50 | 12 |
E32-T24E 2M | 450 | 220 | 150 | 39 | ||
Top-view | E32-T21-S1 2M | 510 | 250 | 170 | 44 | |
E32-TC200BR 2M | 1,870 | 910 | 700 | 180 | ||
Reflective | Side-view | E32-D24R 2M | 68 | 28 | 20 | 5 |
E32-D24-S2 2M | 150 | 64 | 45 | 13 | ||
Top-view | E32-D43M 1M | 29 | 12 | 8 | 2 | |
E32-D331 2M | 13 | 5 | 4 | 1 | ||
E32-D33 2M | 68 | 28 | 20 | 5 | ||
E32-D32-S1 0.5M | 68 | 28 | 18 | 5 | ||
E32-D31-S1 0.5M | 68 | 28 | 20 | 5 | ||
E32-DC200F4R 2M | 130 | 57 | 40 | 11 | ||
E32-D22-S1 2M | 220 | 96 | 72 | 19 | ||
E32-D21-S3 2M | 220 | 96 | 72 | 19 | ||
E32-DC200BR 2M | 800 | 320 | 240 | 72 | ||
E32-D25-S3 2M | 220 | 96 | 72 | 19 |
Type | Spot
diameter |
Center
distance (mm) |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Variable
spot |
0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
Parallel
light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
E32-C21N 2M + E39-F3C | Spot diameter of 0.2 mm at 17 mm. | ||||||
Integrated
lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm.
(For all the sensing distance modes (40 to 100mm)) |
||||
Small-
spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
E32-C21N 2M + E39-F3A-5 | |||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
E32-C21N 2M + E39-F3B | |||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
E32-C11N 2M + E39-F18 |
Type | Sensing
direction |
Aperture
angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam models with integrated lens |
Right-angle | 15° | E32-LT11N 2M | 4,000 *2 | 2,990 | 2,300 | 590 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 5,200 | |
15° | E32-LT11 2M | 4,000 *2 | 3,510 | 2,700 | 700 | ||
E32-LT11R 2M | 4,000 *2 | 2,990 | 2,300 | 590 | |||
Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,160 | |
Through-
beam models with lenses |
Right-angle | 12° | E32-T11N 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,270 |
6° | E32-T11N 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,290 | ||
Top-view | 12° | E32-T11R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,270 | |
6° | E32-T11R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,290 | ||
Side-view | 60° | E32-T11R 2M + E39-F2 | 1,680 | 810 | 630 | 160 | |
Top-view | 12° | E32-T11 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,630 | |
6° | E32-T11 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,940 | ||
Side-view | 60° | E32-T11 2M + E39-F2 | 2,170 | 1,050 | 810 | 210 | |
Top-view | 12° | E32-T51R 2M + E39-F1 | 4,000 *2 | 2,850 | 2,190 | 570 | |
6° | E32-T51R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,830 | ||
Side-view | 60° | E32-T51R 2M + E39-F2 | 1,430 | 690 | 530 | 130 | |
Top-view | 12° | E32-T81R-S 2M + E39-F1 | 4,000 *2 | 3,270 | 2,520 | 650 | |
6° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,170 | ||
Side-view | 60° | E32-T81R-S 2M + E39-F2 | 860 | 420 | 320 | 84 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,090 | |
6° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,960 | ||
Side-view | 60° | E32-T61-S 2M + E39-F2 | 1,440 | 700 | 540 | 140 | |
Top-view | 12° | E32-T51 2M + E39-F1-33 | 4,000 *2 | 2,990 | 2,300 | 590 | |
6° | E32-T51 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,270 | ||
Reflective
models with integrated lens |
Top-view | 4° | E32-D16 2M | 40 to 4,000 *2 | 40 to 2,100 | 40 to 1,350 | 40 to 480 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Sensing
direction |
Aperture
angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
||||
Through-
beam |
Side-view | 1.5° | E32-A03 2M | 3,210 | 1,560 | 1,200 | 310 |
E32-A03-1 2M | 3,210 | 1,560 | 1,200 | 310 | |||
3.4° | E32-A04 2M | 1,200 | 580 | 450 | 110 | ||
4° | E32-T24SR 2M | 3,930 | 1,910 | 1,460 | 380 | ||
E32-T24S 2M | 4,000 *1 | 2,270 | 1,740 | 450 | |||
E32-T22S 2M | 4,000 *1 | 3,250 | 2,500 | 650 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
|||
Limited-
reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-L24S 2M | 0 to 4 | |||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Sensing
method |
Feature | Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Retro-
reflective |
Film detection | M3 | E32-C31 2M+
E39-F3R+E39-RP37 |
230 | 200 | --- | |
Square | --- | E32-R16 5M | 150 to 1,500 | ||||
Threaded | M6 | E32-R21 2M | 10 to 250 | ||||
Hex-shaped | E32-LR11NP 2M+
E39-RP1 |
1,280 | 1,080 | 1,000 | 360 |
Sensing
method |
Feature | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
||||
Limited-
reflective |
Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
Glass substrate
alignment, 70°C |
E32-A08 2M | 15 to 25 | --- | ||||
Standard/
long-distance |
E32-A12 2M | 12 to 30 | --- | ||||
Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
Glass substrate
mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 | --- |
Sensing
method |
Type | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,340 |
Chemical/
oil-resistant |
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,040 | |
E32-T11F 2M | 4,000 *1 | 3,380 | 2,600 | 670 | |||
Side-view | E32-T14F 2M | 1,340 | 650 | 500 | 130 | ||
Chemical/
oil-resistant at 150°C |
Top-view | E32-T51F 2M | 4,000 *1 | 2,340 | 1,800 | 460 | |
Reflective | Semiconductors:
Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 2M | 8 to 20 mm from tip of lens
(Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Semiconductors:
Resist stripping; 85°C |
E32-L11FS 2M | 8 to 20 mm from tip of lens
(Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||||
Chemical/
oil-resistant |
E32-D12F 2M | --- *2 | 170 | 130 | 39 | ||
Chemical-
resistant cable |
E32-D11U 2M | 800 | 320 | 240 | 72 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
*2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin.
Sensing
method |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
|||
Through-
beam |
1.5 dia. | E32-T22B 2M | 750 | 370 | 220 | 65 |
M3 | E32-T21 2M | 670 | 330 | 220 | 58 | |
M4 | E32-T11 2M | 2,410 | 1,170 | 900 | 230 | |
Square | E32-T25XB 2M | 500 | 250 | 170 | 43 | |
Reflective | 1.5 dia. | E32-D22B 2M | 130 | 57 | 40 | 11 |
M3 | E32-D21 2M | 130 | 57 | 40 | 11 | |
3 dia. | E32-D221B 2M | 310 | 120 | 90 | 26 | |
M4 | E32-D21B 2M | 310 | 120 | 90 | 26 | |
M6 | E32-D11 2M | 800 | 320 | 240 | 72 | |
Square | E32-D25XB 2M | 220 | 92 | 60 | 18 |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
|||
Through-
beam |
100°C | E32-T51R 2M | 1,500 | 720 | 560 | 140 |
150°C | E32-T51 2M | 2,680 | 1,300 | 1,000 | 260 | |
200°C | E32-T81R-S 2M | 960 | 460 | 360 | 93 | |
350°C | E32-T61-S 2M | 1,600 | 780 | 600 | 150 | |
Reflective | 100°C | E32-D51R 2M | 640 | 250 | 190 | 57 |
150°C | E32-D51 2M | 1,070 | 430 | 320 | 96 | |
200°C | E32-D81R-S 2M | 380 | 150 | 120 | 34 | |
300°C | E32-A08H2 2M | 15 to 25 | --- | |||
E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
350°C | E32-D61-S 2M | 380 | 150 | 120 | 34 | |
400°C | E32-D73-S 2M | 250 | 100 | 80 | 22 |
Sensing
method |
Type | Sensing
width |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed mode | Super-high-
speed mode |
||||
Through-
beam |
Area | 11 mm | E32-T16PR 2M | 3,010 | 1,460 | 1,120 | 290 |
E32-T1s6JR 2M | 2,610 | 1,260 | 970 | 250 | |||
30 mm | E32-T16WR 2M | 4,000 *1 | 2,240 | 1,720 | 440 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 670 | 270 | 200 | 60 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Tube
diameter |
Feature | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Tube-
mounting |
3.2, 6.4,
or 9.5 dia |
Stable residual
quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm,
Recommended wall thickness: 1 mm |
|||
8 to 10 dia | Mounting at
multiple levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to 10 mm,
Recommended wall thickness: 1 mm |
||||
No restrictions | Large tubes | E32-D36T 2M | Applicable tube: Transparent tube (no restrictions on diameter) | ||||
Liquid contact
(heat-resistant up to 200°C) |
--- | --- | E32-D82F1 4M | Liquid-contact type |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||
Through-
beam |
120°C | E32-T51V 1M | 690 | 330 | 260 | 67 |
E32-T51V 1M+E39-F1V | 2,000 *1 | 1,760 | 1,360 | 350 | ||
200°C | E32-T84SV 1M | 1,710 | 830 | 640 | 160 |
*1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm.
Sensing
method |
Application | Operating
temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Limited-
reflective |
Glass
presence detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
Glass
substrate alignment |
E32-A08 2M | 15 to 25 | --- | ||||
300°C | E32-A08H2 2M | 15 to 25 | --- | ||||
70°C | E32-A12 2M | 12 to 30 | --- | ||||
Glass
substrate mapping |
E32-A09 2M | 15 to 38 | --- | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
Wet processes:
Cleaning, Resist developing and etching |
60°C | E32-L11FP 2M | 8 to 20 mm from tip of lens
(Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||||
Wet process:
Resist stripping |
85°C | E32-L11FS 2M | 8 to 20 mm from tip of lens
(Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Through-
beam |
Wafer mapping | 70°C | E32-A03 2M | 3,210 | 1,560 | 1,200 | 310 |
E32-A03-1 2M | 3,210 | 1,560 | 1,200 | 310 | |||
E32-A04 2M | 1,200 | 580 | 450 | 110 | |||
E32-T24SR 2M | 3,930 | 1,910 | 1,460 | 380 | |||
E32-T24S 2M | 4,000 *1 | 2,270 | 1,740 | 450 |
*1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
last update: April 1, 2020