Smart Fiber Amplifier Units
last update: July 1, 2021
Type | Standard models | |||
---|---|---|---|---|
NPN output | E3NX-FA11 | E3NX-FA6 | E3NX-FA11-5 *1 | |
PNP output | E3NX-FA41 | E3NX-FA8 | --- | |
Connecting method | Pre-wired | Wire-saving Connector | Pre-wired | |
Inputs/
outputs |
Outputs | 1 output | ||
External inputs | --- | |||
Light source (wavelength) | Red, 4-element LED (625 nm) | |||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||
Power consumption *2 | At Power supply voltage of 24 VDC
Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.) Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.) Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
|||
Control output | Load power supply voltage: 30 VDC max., open-collector output
(depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
|||
External inputs | --- | |||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
|||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | |||
Response
time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | ||
High-speed mode (HS) | Operate or reset: 250 μs | |||
Standard mode (Stnd) | Operate or reset: 1 ms | |||
Giga-power mode (GIGA) | Operate or reset: 16 ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||
Maximum connectable Units | 30 | |||
No. of
Units for mutual interference prevention *4 |
Super-high-speed mode (SHS) | 0
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
||
High-speed mode (HS) | 10 | |||
Standard mode (Stnd) | 10 | |||
Giga-power mode (GIGA) | 10 | |||
Functions | Automatic power control
(APC) |
Always enabled. | ||
Dynamic power control
(DPC) |
Provided | |||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
+ OFF-delay timer: 1 to 9,999 ms |
|||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||
Eco mode *6 | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||
Bank switching | Select from banks 1 to 4. | |||
Power tuning | Select from ON, OFF or Execution on power-up. | |||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode. | |||
Output 2 | --- | |||
External input | --- | |||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||
Ambient temperature range *7 | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation)
within the surrounding air temperature range shown above |
|||
Altitude | 2,000 m max. | |||
Installation environment | Pollution degree 3 | |||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||
Weight (packed state/Sensor only) | Approx. 115 g/
approx. 75 g |
Approx. 60 g/
approx. 20 g |
Approx. 115 g/
approx. 75 g |
|
Materials | Case | Polycarbonate (PC) | ||
Cover | Polycarbonate (PC) | |||
Cable | PVC | |||
Accessories | Instruction Manual |
Type | Advanced models | |||||
---|---|---|---|---|---|---|
NPN output | E3NX-FA21 | E3NX-FA7 | E3NX-FA7TW | E3NX-FA24 | --- | |
PNP output | E3NX-FA51 | E3NX-FA9 | E3NX-FA9TW | E3NX-FA54 | E3NX-FA54TW | |
Connecting method | Pre-wired | Wire-saving Connector | M8 Connector | |||
Inputs/
outputs |
Outputs | 2 outputs | 1 output | 2 outputs | 1 output | 2 outputs |
External inputs | 1 input | 1 input | --- | 1 input | --- | |
Light source (wavelength) | Red, 4-element LED (625 nm) | |||||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | |||||
Power consumption *2 | At Power supply voltage of 24 VDC
Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.) Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.) Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
|||||
Control output | Load power supply voltage: 30 VDC max., open-collector output
(depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
|||||
External inputs | Refer to *3. | --- | Refer to *3. | --- | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
|||||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection,
and output reverse polarity protection |
|||||
Response
time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | ||||
High-speed mode (HS) | Operate or reset: 250 μs | |||||
Standard mode (Stnd) | Operate or reset: 1 ms | |||||
Giga-power mode (GIGA) | Operate or reset: 16 ms | |||||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | |||||
Maximum connectable Units | 30 | |||||
No. of
Units for mutual interference prevention *4 |
Super-high-speed mode (SHS) | 0
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
||||
High-speed mode (HS) | 10 | |||||
Standard mode (Stnd) | 10 | |||||
Giga-power mode (GIGA) | 10 | |||||
Functions | Automatic power control
(APC) |
Always enabled. | ||||
Dynamic power control
(DPC) |
Provided | |||||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
+ OFF-delay timer: 1 to 9,999 ms |
|||||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | |||||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | |||||
Eco mode *6 | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | |||||
Bank switching | Select from banks 1 to 4. | |||||
Power tuning | Select from ON, OFF or Execution on power-up. | |||||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode. | |||||
Output 2 | Select from
normal detection mode, alarm output mode, error output mode or differential detection mode. |
--- | Select from
normal detection mode, alarm output mode, error output mode or differential detection mode. |
--- | Select from
normal detection mode, alarm output mode, error output mode or differential detection mode. |
|
External input | Select from input OFF,
tuning, power tuning, emission OFF, Sensor OFF, zero reset, or bank switching. |
--- | Select
from input OFF, tuning, power tuning, emission OFF, Sensor OFF, zero reset, or bank switching. |
--- | ||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | |||||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | |||||
Ambient temperature range *7 | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
|||||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation)
within the surrounding air temperature range shown above |
|||||
Altitude | 2,000 m max. | |||||
Installation environment | Pollution degree 3 | |||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | |||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | |||||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | |||||
Weight (packed state/Sensor only) | Approx. 115 g/
approx. 75 g |
Approx. 60g/approx. 20g | Approx. 65 g/
approx. 25 g |
|||
Materials | Case | Polycarbonate (PC) | ||||
Cover | Polycarbonate (PC) | |||||
Cable | PVC | |||||
Accessories | Instruction Manual |
Type | Infrared models | ||
---|---|---|---|
NPN output | E3NX-FAH11 | E3NX-FAH6 | |
PNP output | E3NX-FAH41 | E3NX-FAH8 | |
Connecting method | Pre-wired | Wire-saving
Connector |
|
Inputs/
outputs |
Outputs | 1 outputs | |
External inputs | --- | ||
Light source (wavelength) | Infrared LED (870nm) | ||
Power supply voltage | 10 to 30 VDC, including 10% ripple (p-p) | ||
Power consumption *2 | At Power supply voltage of 24 VDC
Standard Models: Normal mode: 840 mW max. (Current consumption at 35 mA max.) Eco function ON: 650 mW max. (Current consumption at 27 mA max.) Eco function LO: 750 mW max. (Current consumption at 31 mA max.) Advanced Models or Model for Sensor Communications Unit: Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 28 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.) Infrared models: Normal mode: 1080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1020 mW max. (Current consumption at 42 mA max.) |
||
Control output | Load power supply voltage: 30 VDC max., open-collector output
(depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
||
External inputs | --- | ||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||
Protection circuits | Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection | ||
Response
time |
Super-high-speed mode (SHS) | Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs | |
High-speed mode (HS) | Operate or reset: 250 μs | ||
Standard mode (Stnd) | Operate or reset: 1 ms | ||
Giga-power mode (GIGA) | Operate or reset: 16 ms | ||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment | ||
Maximum connectable Units | 30 | ||
No. of
Units for mutual interference prevention *4 |
Super-high-speed mode (SHS) | 0
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled. |
|
High-speed mode (HS) | 10 | ||
Standard mode (Stnd) | 10 | ||
Giga-power mode (GIGA) | 10 | ||
Functions | Automatic power control
(APC) |
Always enabled. | |
Dynamic power control
(DPC) |
Provided | ||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay
+ OFF-delay timer: 1 to 9,999 ms |
||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||
Resetting settings *5 | Select from initial reset (factory defaults) or user reset (saved settings). | ||
Eco mode *6 | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). | ||
Bank switching | Select from banks 1 to 4. | ||
Power tuning | Select from ON or OFF. | ||
Output 1 | Select from normal detection mode or area detection mode. | ||
Output 2 | --- | ||
External input | --- | ||
Hysteresis width | Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. | ||
Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||
Ambient temperature range *7 | Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation)
within the surrounding air temperature range shown above |
||
Altitude | 2,000 m max. | ||
Installation environment | Pollution degree 3 | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||
Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||
Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | ||
Weight (packed state/Sensor only) | Approx. 115 g/approx. 75 g | Approx. 60g/approx. 20g | |
Materials | Case | Polycarbonate (PC) | |
Cover | Polycarbonate (PC) | ||
Cable | PVC | ||
Accessories | Instruction Manual |
Contact input (relay or switch) | Non-contact input (transistor) | Input time*3-1 | |
---|---|---|---|
NPN | ON: Shorted to 0 V (Sourcing current: 1 mA
max.). OFF: Open or shorted to Vcc. |
ON: 1.5 V max. (Sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 mA max.) |
ON: 9 ms min.
OFF: 20 ms min. |
PNP | ON: Shorted to Vcc (Sinking current: 3 mA
max.). OFF: Open or shorted to 0 V. |
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA
max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.) |
Type | Analog output
models |
Model for Sensor Communications Unit | |||
---|---|---|---|---|---|
NPN output | E3NX-FA11AN | E3NX-FA10 | E3NX-FA0 | E3NX-FAH0 | |
PNP output | E3NX-FA41AN | E3NX-FA40 | |||
Connecting method | Pre-wired | Connector for
Sensor Communications Unit Pre-wired |
Connector for Sensor
Communications Unit |
||
Inputs/
outputs |
Outputs | 2 outputs | 1 outputs | --- *1 | |
External
inputs |
--- | --- | |||
Light source
(wavelength) |
Red, 4-element LED (625 nm) | Infrared LED (870nm) | |||
Power supply voltage | 10 to 30 VDC, including
10% ripple (p-p) |
Supplied from the connector through the communication units. | |||
Power consumption *2 | At Power supply
voltage of 24 VDC Normal mode: 960 mW max. (Current consumption at 40 mA max.) Eco function ON: 770 mW max. (Current consumption at 32 mA max.) Eco function LO: 870 mW max. (Current consumption at 36 mA max.) |
At Power supply voltage of 24
VDC Normal mode: 920 mW max. (Current consumption at 38 mA max.) Eco function ON: 680 mW max. (Current consumption at 26 mA max.) Eco function LO: 800 mW max. (Current consumption at 33 mA max.) |
At Power supply voltage
of 24 VDC Normal mode: 1,080 mW max. (Current consumption at 45 mA max.) Eco function ON: 920 mW max. (Current consumption at 38 mA max.) Eco function LO: 1,020 mW max. (Current consumption at 42 mA max.) |
||
Control output | Load power supply voltage:
30 VDC max., open-collector output (depends on the NPN/PNP output format) Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. (Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max.) OFF current: 0.1 mA max. |
--- | |||
Analog output
(reference value) |
Voltage output: 1-5 VDC
(10 kΩ or more connected load), temperature characteristics: 0.3% F.S. / °C |
--- | |||
Indicators | 7-segment displays (Sub digital display: green, Main digital display: white)
Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) |
||||
Protection circuits | Power supply reverse polarity protection,
output short-circuit protection, and output reverse polarity protection |
Power supply reverse polarity
protection and output short-circuit protection |
|||
Control
output Response time |
Super-high-
speed mode (SHS) |
Operate or reset:
80 μs |
Operate or reset: 32 μs | ||
High-speed
mode (HS) |
Operate or reset:
250μs |
Operate or reset: 250 μs | |||
Standard
mode (Stnd) |
Operate or reset:
1 ms |
Operate or reset: 1 ms | |||
Giga-power
mode (GIGA) |
Operate or reset:
16 ms |
Operate or reset: 16 ms | |||
Sensitivity adjustment | Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning,
power tuning, percentage tuning (-99% to 99%)) or manual adjustment |
||||
Maximum connectable Units | 30 | 16 | With E3NW-ECT: 30 units
(When connected to an OMRON NJ- series Controller.) With E3NW-CRT: 16 units (Note: E3NX-FAH0 can not be connected.) With E3NW-CCL: 16 units |
||
No. of
Units for mutual inter- ference preven- tion *3 |
Super-high-
speed mode (SHS) |
0 (The mutual interference prevention function is disabled if the detection mode is set to
super-high-speed mode.) |
|||
High-speed
mode (HS) |
10 | ||||
Standard
mode (Stnd) |
10 | ||||
Giga-power
mode (GIGA) |
10 | ||||
Func-
tions |
Automatic
power control (APC) |
Always enabled. | |||
Dynamic
power control (DPC) |
Provided | ||||
Timer | Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer:
1 to 9,999 ms |
||||
Zero reset | Negative values can be displayed. (Threshold value is shifted.) | ||||
Resetting
settings *4 |
Select from initial reset (factory defaults) or user reset (saved settings). | ||||
Eco mode | Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display
dimmed). |
||||
Bank
switching |
Select from banks 1 to 4. | ||||
Sensor OFF
setting |
--- | Select from
ON or OFF. |
--- | ||
Power
tuning |
Select from ON or OFF. | ||||
Output 1 | Select from normal detection mode, area detection mode or differential detection mode
(E3NX-FA10/40 only). |
||||
Output 2 | Select from Analog
scaling or Analog offset |
--- | Select from normal detection mode,
alarm output mode, error output mode or differential detection mode (E3NX- FA0 only). |
||
Hysteresis
width |
Select from standard setting or user setting. For a user setting, the hysteresis width can
be set from 0 to 9,999. |
||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
Ambient temperature
range *5 |
Operating:
Groups of 1 or 2 Amplifier Units: -25 to 55°C, Groups of 3 to 10 Amplifier Units: -25 to 50°C, Groups of 11 to 16 Amplifier Units: -25 to 45°C, Groups of 17 to 30 Amplifier Units: -25 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C Storage: -30 to 70°C (with no icing or condensation) |
Operating:
Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) |
||
Ambient humidity range | Operating and storage: 35 to 85% (with no condensation) within the surrounding air
temperature range shown above |
||||
Altitude | 2,000 m max. | ||||
Installation environment | Pollution degree 3 | ||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||
Vibration resistance
(destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance
(destruction) |
500 m/s2 for 3 times
each in X, Y, and Z directions |
150 m/s2 for 3 times each in X, Y, and Z directions | |||
Weight (packed state/
Sensor only) |
Approx. 115 g/
approx. 75 g |
Approx. 95 g/
approx. 45 g |
Approx. 65 g/
approx. 25 g |
Approx. 65 g/
approx. 25 g |
|
Materials | Case | Polycarbonate (PC) | |||
Cover | Polycarbonate (PC) | ||||
Cable | PVC | ||||
Accessories | Instruction Manual |
*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table.
PLC operation via Communications Unit enables reading detected values and changing settings.
*2. At Power supply voltage of 10 to 30 VDC
Analog output models:
Normal mode : 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC)
Eco function ON : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC)
Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC)
*3. The tuning will not change the number of units.
The least unit count among the mutual interference prevention units of E3NX and E3NC.
Check the mutual interference prevention unit count and response speed of each model.
*4. The bank is not reset by the user reset function or saved by the user save function.
*5. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.
Sensing
method |
Sensing
direction |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
||||
Through-beam | Right-angle | M4 | E32-T11N 2M | 3,000 | 1,500 | 1,050 | 280 |
E32-LT11N 2M | 4,000*1 | 4,000*1 | 3,450 | 920 | |||
Straight | E32-T11R 2M | 3,000 | 1,500 | 1,050 | 280 | ||
E32-LT11 2M | 4,000*1 | 4,000*1 | 4,000*1 | 1,080 | |||
E32-LT11R 2M | 4,000*1 | 4,000*1 | 3,450 | 920 | |||
Reflective | Right-angle | M3 | E32-C31N 2M | 160 | 75 | 69 | 14 |
E32-C21N 2M | 440 | 190 | 130 | 39 | |||
M4 | E32-D21N 2M | 1,260 | 520 | 360 | 100 | ||
M6 | E32-C11N 2M | 1,170 | 520 | 480 | 100 | ||
E32-LD11N 2M | 1,260 | 520 | 360 | 100 | |||
Straight | M3 | E32-D21R 2M | 210 | 90 | 60 | 16 | |
E32-C31 2M | 490 | 220 | 150 | 44 | |||
E32-C31M 1M | |||||||
M4 | E32-D211R 2M | 210 | 90 | 60 | 16 | ||
M6 | E32-D11R 2M | 1,260 | 520 | 360 | 100 | ||
E32-CC200 2M | 2,100 | 900 | 600 | 180 | |||
E32-LD11 2M | 1,290 | 540 | 370 | 110 | |||
E32-LD11R 2M | 1,260 | 520 | 360 | 100 |
Sensing
method |
Size | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam |
1 dia. | Top-view | E32-T223R 2M | 670 | 370 | 220 | 60 |
1.5 dia. | E32-T22B 2M | 1,020 | 600 | 330 | 90 | ||
3 dia. | E32-T12R 2M | 3,000 | 1,500 | 1,050 | 280 | ||
Side-view | E32-T14LR 2M | 1,120 | 670 | 390 | 100 | ||
Reflective | 1.5 dia. | Top-view | E32-D22B 2M | 210 | 90 | 60 | 16 |
1.5 dia. + 0.5 dia. | E32-D43M 1M | 42 | 18 | 12 | 4 | ||
3 dia. | E32-D22R 2M | 210 | 90 | 60 | 16 | ||
E32-D221B 2M | 450 | 210 | 130 | 40 | |||
E32-D32L 2M | 1,050 | 450 | 300 | 90 | |||
3 dia. + 0.8 dia. | E32-D33 2M | 100 | 45 | 30 | 8 |
Sensing
method |
Sensing direction | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||
Through-beam | Top-view | E32-T15XR 2M | 3,000 | 1,500 | 1,050 | 280 |
Side-view | E32-T15YR 2M | 1,120 | 670 | 390 | 100 | |
Flat-view | E32-T15ZR 2M | |||||
Reflective | Top-view | E32-D15XR 2M | 1,260 | 520 | 360 | 100 |
Side-view | E32-D15YR 2M | 300 | 150 | 78 | 24 | |
Flat-view | E32-D15ZR 2M |
Sensing
method |
Sensing direction | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||
Through-beam | Side-view | E32-T24R 2M | 250 | 150 | 75 | 20 |
E32-T24E 2M | 670 | 370 | 220 | 60 | ||
Top-view | E32-T33 1M | 220 | 130 | 75 | 20 | |
E32-T21-S1 2M | 760 | 450 | 250 | 68 | ||
E32-TC200BR 2M | 3,000 | 1,500 | 1,050 | 280 | ||
Reflective | Side-view | E32-D24R 2M | 100 | 45 | 30 | 8 |
E32-D24-S2 2M | 180 | 79 | 67 | 14 | ||
Top-view | E32-D43M 1M | 42 | 18 | 12 | 4 | |
E32-D331 2M | 21 | 9 | 6 | 2 | ||
E32-D33 2M | 100 | 45 | 30 | 8 | ||
E32-D32-S1 0.5M | 94 | 40 | 27 | 7 | ||
E32-D31-S1 0.5M | ||||||
E32-DC200F4R 2M | 210 | 90 | 60 | 16 | ||
E32-D22-S1 2M | 370 | 160 | 100 | 30 | ||
E32-D21-S3 2M | ||||||
E32-DC200BR 2M | 1,260 | 520 | 360 | 100 | ||
E32-D25-S3 2M | 370 | 160 | 100 | 30 |
Type | Spot
diameter |
Center
distance (mm) |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Variable
spot |
0.1 to 0.6 dia. | 6 to 15 | E32-C42 1M + E39-F3A | Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. | |||
0.3 to 1.6 dia. | 10 to 30 | E32-C42 1M + E39-F17 | Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. | ||||
Parallel
light |
4 dia. | 0 to 20 | E32-C31 2M + E39-F3C | Spot diameter of 4 mm max. at 0 to 20 mm. | |||
E32-C31N 2M + E39-F3C | |||||||
Integrated
lens |
0.1 dia. | 5 | E32-C42S 1M | Spot diameter of 0.1 mm at 5 mm. | |||
6 dia. | 50 | E32-L15 2M | Spot diameter of 6 mm at 50 mm. | ||||
Small-
spot |
0.1 dia. | 7 | E32-C41 1M + E39-F3A-5 | Spot diameter of 0.1 mm at 7 mm. | |||
0.5 dia. | E32-C31 2M + E39-F3A-5 | Spot diameter of 0.5 mm at 7 mm. | |||||
E32-C31N 2M + E39-F3A-5 | |||||||
0.2 dia. | 17 | E32-C41 1M + E39-F3B | Spot diameter of 0.2 mm at 17 mm. | ||||
0.5 dia. | E32-C31 2M + E39-F3B | Spot diameter of 0.5 mm at 17 mm. | |||||
E32-C31N 2M + E39-F3B | |||||||
3 dia. | 50 | E32-CC200 2M + E39-F18 | Spot diameter of 3 mm at 50 mm. | ||||
E32-C11N 2M + E39-F18 |
Type | Sensing
direction |
Center
distance (mm) |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-
speed mode |
Super-
high- speed mode |
||||
Through-beam
models with integrated lens |
Right-angle | 15° | E32-LT11N 2M | 4,000*2 | 4,000*2 | 3,450 | 920 |
Top-view | 10° | E32-T17L 10M | 20,000 *1 | 20,000 *1 | 20,000 *1 | 8,000 | |
15° | E32-LT11 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,080 | ||
E32-LT11R 2M | 4,000 *2 | 4,000 *2 | 3,450 | 920 | |||
Side-view | 30° | E32-T14 2M | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
Through-beam
models with lenses |
Right-angle | 12° | E32-T11N 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 |
6° | E32-T11N 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Top-view | 12° | E32-T11R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 2,000 | |
6° | E32-T11R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,600 | ||
Side-view | 60° | E32-T11R 2M + E39-F2 | 2,170 | 1,200 | 750 | 200 | |
Top-view | 12° | E32-T11 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,860 | |
6° | E32-T11 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60° | E32-T11 2M + E39-F2 | 3,450 | 1,980 | 1,290 | 320 | |
Top-view | 12° | E32-T51R 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,500 | |
6° | E32-T51R 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Side-view | 60° | E32-T51R 2M + E39-F2 | 2,100 | 1,080 | 750 | 200 | |
Top-view | 12° | E32-T81R-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,000 | |
6° | E32-T81R-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | ||
Side-view | 60° | E32-T81R-S 2M + E39-F2 | 1,500 | 820 | 540 | 140 | |
Top-view | 12° | E32-T61-S 2M + E39-F1 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 1,800 | |
6° | E32-T61-S 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 3,100 | ||
Side-view | 60° | E32-T61-S 2M + E39-F2 | 2,520 | 1,350 | 900 | 240 | |
Top-view | 12° | E32-T51 2M + E39-F1-33 | 4,000 *2 | 4,000 *2 | 3,450 | 1,400 | |
6° | E32-T51 2M + E39-F16 | 4,000 *2 | 4,000 *2 | 4,000 *2 | 4,000 *2 | ||
Reflective
models with integrated lens |
Top-view | 4° | E32-D16 2M | 40 to
4,200 |
40 to
2,100 |
40 to
1,350 |
40 to 720 |
*1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
*2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Sensing
method |
Sensing
direction |
Aperture
angle |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Through-beam | Side-view | 1.5° | E32-A03 2M | 4,000 *1 | 2,670 | 1,800 | 500 |
E32-A03-1 2M | |||||||
3.4° | E32-A04 2M | 1,920 | 1,020 | 670 | 200 | ||
4° | E32-T24SR 2M | 4,000 *1 | 3,300 | 2,190 | 580 | ||
E32-T24S 2M | 4,000 *1 | 3,900 | 2,610 | 700 | |||
E32-T22S 2M | 4,000 *1 | 4,000 *1 | 3,750 | 1,000 |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-speed
mode |
|||
Limited-
reflective |
Flat-view | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-L24S 2M | 0 to 4 | |||||
Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) |
Sensing
method |
Feature | Size | Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Retro-
reflective |
Film detection | M3 | E32-C31 2M + E39-F3R +
E39-RP37 |
370 | 300 | --- | |
Square | --- | E32-R16 5M | 150 to 1,500 | ||||
Threaded | M6 | E32-R21 2M | 10 to 370 | 10 to 250 | |||
Hex-shaped | E32-LR11NP 2M +
E39-RP1 |
2,020 | 1,800 | 1,500 | 550 |
Sensing
method |
Feature | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga
mode |
Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Limited-
reflective |
Small size | Flat-view | E32-L24S 2M | 0 to 4 | |||
Standard | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||||
Glass substrate
alignment, 70°C |
E32-A08 2M | 10 to 20 | --- | ||||
Standard/long-distance | E32-A12 2M | 12 to 30 | --- | ||||
Side-view form | Side-view | E32-L25L 2M | 5.4 to 9 (center 7.2) | ||||
Glass substrate
mapping, 70°C |
Top-view | E32-A09 2M | 15 to 38 | --- |
Sensing
method |
Type | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam |
Oil-resistant | Right-angle | E32-T11NF 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 2,200 |
Chemical/
oil-resistant |
Top-view | E32-T12F 2M | 4,000 *1 | 4,000 *1 | 4,000 *1 | 1,600 | |
E32-T11F 2M | 4,000 *1 | 4,000 *1 | 3,900 | 1,000 | |||
Side-view | E32-T14F 2M | 2,100 | 1,200 | 750 | 200 | ||
Chemical/
oil-resistant at 150°C |
Top-view | E32-T51F 2M | 4,000 *1 | 4,000 *1 | 2,700 | 700 | |
Reflective | Semiconductors:
Cleaning, developing, and etching; 60°C |
Top-view | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing
distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
|||
Semiconductors:
Resist stripping; 85°C |
E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing
distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
|||||
Chemical/
oil-resistant |
E32-D12F 2M | --- *2 | 280 | 190 | 60 | ||
Chemical-
resistant cable |
E32-D11U 2M | 1,260 | 520 | 360 | 100 |
Sensing
method |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-speed
mode |
|||
Through-beam | 1.5 dia. | E32-T22B 2M | 1,020 | 600 | 330 | 90 |
M3 | E32-T21 2M | |||||
M4 | E32-T11 2M | 3,750 | 2,020 | 1,350 | 360 | |
Square | 32-T25XB 2M | 750 | 450 | 250 | 70 | |
Reflective | 1.5 dia. | E32-D22B 2M | 210 | 90 | 60 | 16 |
M3 | E32-D21 2M | |||||
3 dia. | E32-D221B 2M | 450 | 210 | 130 | 40 | |
M4 | E32-D21B 2M | |||||
M6 | E32-D11 2M | 1,260 | 520 | 360 | 100 | |
Square | E32-D25XB 2M | 360 | 150 | 90 | 30 |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
|||
Through-beam | 100°C | E32-T51R 2M | 2,400 | 1,200 | 840 | 225 |
150°C | E32-T51 2M | 4,000 *1 | 2,250 | 1,500 | 400 | |
200°C | E32-T81R-S 2M | 1,500 | 820 | 540 | 140 | |
350°C | E32-T61-S 2M | 2,520 | 1,350 | 900 | 240 | |
Reflective | 100°C | E32-D51R 2M | 1,000 | 420 | 280 | 80 |
150°C | E32-D51 2M | 1,680 | 670 | 480 | 144 | |
200°C | E32-D81R-S 2M | 630 | 270 | 180 | 54 | |
300°C | E32-A08H2 2M | 10 to 20 | --- | |||
E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
350°C | E32-D611-S 2M | 630 | 270 | 180 | 54 | |
E32-D61-S 2M | ||||||
400°C | E32-D73-S 2M | 420 | 180 | 120 | 36 |
Sensing
method |
Type | Sensing width | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Through-beam | Area | 11 mm | E32-T16PR 2M | 4,000 *1 | 2,550 | 1,680 | 440 |
E32-T16JR 2M | 4,000 *1 | 2,250 | 1,440 | 380 | |||
30 mm | E32-T16WR 2M | 4,000 *1 | 3,900 | 2,550 | 680 | ||
Reflective | Array | 11 mm | E32-D36P1 2M | 1,050 | 450 | 300 | 90 |
Sensing
method |
Tube
diameter |
Feature | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Tube-
mounting |
3.2, 6.4, or
9.5 dia |
Stable
residual quantity detection |
E32-A01 5M | Applicable tube: Transparent tube with a diameter of 3.2,
6.4, or 9.5 mm, Recommended wall thickness: 1 mm |
|||
8 to 10 dia | Mounting at
multiple levels |
E32-L25T 2M | Applicable tube: Transparent tube with a diameter of 8 to
10 mm, Recommended wall thickness: 1 mm |
||||
No
restrictions |
Large tubes | E32-D36T 5M | Applicable tube: Transparent tube (no restrictions on
diameter) |
||||
Liquid contact
(heat-resistant up to 200°C) |
--- | --- | E32-D82F1 4M | Liquid-contact type |
Sensing
method |
Heat-resistant
temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
|||
Through-beam | 120 °C | E32-T51V 1M | 1,080 | 600 | 390 | 100 |
E32-T51V 1M + E39-F1V | 2,000 *1 | 2,000 *1 | 2,000 *1 | 520 | ||
200 °C | E32-T84SV 1M | 2,000*1 | 1,420 | 960 | 260 |
Sensing
method |
Application | Operating
temperature |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard
mode |
High-speed
mode |
Super-high-
speed mode |
||||
Limited-
reflective |
Glass presence
detection |
70°C | E32-L16-N 2M | 0 to 15 | 0 to 12 | ||
E32-A08 2M | 10 to 20 | --- | |||||
Glass substrate
alignment |
300°C | E32-A08H2 3M | |||||
70°C | E32-A12 2M | 12 to 30 | --- | ||||
Glass substrate
mapping |
E32-A09 2M | 15 to 38 | --- | ||||
300°C | E32-A09H2 2M | 20 to 30 (center 25) | --- | ||||
Wet processes:
Cleaning, Resist developing and etching |
60°C | E32-L11FP 5M | 8 to 20 mm from tip of lens (Recommended sensing
distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
||||
Wet process:
Resist stripping |
85°C | E32-L11FS 5M | 8 to 20 mm from tip of lens (Recommended sensing
distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
||||
Through-
beam |
Wafer mapping | 70°C | E32-A03 2M | 4,000 *1 | 2,670 | 1,800 | 500 |
E32-A03-1 2M | |||||||
E32-A04 2M | 1,920 | 1,020 | 670 | 200 | |||
E32-T24SR 2M | 4,000 *1 | 3,300 | 2,190 | 580 | |||
E32-T24S 2M | 4,000 *1 | 3,900 | 2,610 | 700 |
Sensing
method |
Sensing
direction |
Size | Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam |
Right-angle | M4 | E32-T11N 2M | 280 | 190 | 130 | 55 |
Straight | E32-T11R 2M | ||||||
Reflective | Straight | M3 | E32-C31 2M | 50 | 37 | 25 | 8.5 |
M6 | E32-D11R 2M | 120 | 90 | 60 | 21 | ||
E32-CC200 2M | 200 | 150 | 100 | 35 |
Sensing
method |
Size | Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
||||
Through-
beam |
3 dia. | Top-view | E32-T12R 2M | 280 | 190 | 130 | 55 |
Side-view | E32-T14LR 2M | 100 | 75 | 80 | 21 | ||
Reflective | 3 dia. | Top-view | E32-D32L 2M | 100 | 75 | 50 | 17 |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
|||
Through-
beam |
Top-view | E32-T15XR 2M | 280 | 190 | 130 | 55 |
Side-view | E32-T15YR 2M | 100 | 75 | 80 | 21 | |
Flat-view | E32-T15ZR 2M | |||||
Reflective | Top-view | E32-D15XR 2M | 120 | 90 | 60 | 21 |
Side-view | E32-D15YR 2M | 28 | 20 | 13 | 5 | |
Flat-view | E32-D15ZR 2M |
Sensing
method |
Sensing
direction |
Model | Sensing distance (mm) | |||
---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
|||
Through-
beam |
Top-view | E32-TC200BR 2M | 280 | 190 | 130 | 55 |
Reflective | Top-view | E32-DC200BR 2M | 120 | 90 | 60 | 21 |
Type | Sensing
direction |
Aperture
angle |
Models | Sensing distance (mm) | |||
---|---|---|---|---|---|---|---|
Giga mode | Standard mode | High-speed
mode |
Super-high-
speed mode |
||||
Through-beam
models with integrated lens |
Side-view | 30° | E32-T14 2M | 1800 | 1200 | 820 | 360 |
last update: July 1, 2021