Weighing Indicator
last update: August 6, 2015
Power supply voltage | 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC | |
---|---|---|
Allowable power supply voltage
range |
85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25
VDC |
|
Power consumption *1 | 100 to 240 V: 18 VA max. (max. load)
24 VAC/DC: 11 VA/7 W max. (max. load) |
|
Current consumption | DeviceNet power supply: 50 mA max. (24 VDC) | |
Input | DC voltage | |
A/D conversion method | Delta-Sigma method | |
External power supply | 10 VDC ±5%, 100 mA (models with external power supply only) or 5 VDC, 100 mA
(models with external power supply only) |
|
Event
inputs *2 |
Timing input | NPN open collector or no-voltage contact signal
ON residual voltage: 3 V max. ON current at 0 Ω: 17 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 1.5 mA max. |
Startup compensation
timer input |
NPN open collector or no-voltage contact signal
ON residual voltage: 2 V max. ON current at 0 Ω: 4 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max. |
|
Hold input | ||
Reset input | ||
Forced-zero input | ||
Bank input | ||
Output
ratings (depends on the model) |
Relay output | 250 VAC, 30 VDC, 5 A (resistive load)
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations |
Transistor output | Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current:
100 μA max. |
|
Linear output | Linear output 0 to 20 mA DC, 4 to 20 mA DC:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS (1 V or less: ±0.15 V; no output for 0 V or less) |
|
Display method | Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green) |
|
Main functions | Scaling function, measurement operation selection, averaging, previous average
value comparison, forcedzero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset |
|
Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |
Ambient operating humidity | 25% to 85% | |
Storage temperature | -25 to 65°C (with no icing or condensation) | |
Altitude | 2,000 m max. | |
Accessories | Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual.
DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC (01)) and crimp terminals (Hirose HR31-SC-121) *3 |
Display range | -19,999 to 99,999 | |
---|---|---|
Sampling period | 20 ms (50 times/second) | |
Comparative output
response time |
100 ms max. | |
Linear output response time | 150 ms max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 2,300 VAC for 1 min between external terminals and case | |
Noise immunity | 100 to 240 VAC models: ±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) 24 VAC/VDC models: ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 μs/100 ns) |
|
Vibration resistance | Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z
directions |
|
Shock resistance | 150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions | |
Weight | Approx. 300 g (Base Unit only) | |
Degree of
protection |
Front panel | Conforms to NEMA 4X for indoor use (equivalent to IP66) |
Rear case | IP20 | |
Terminals | IP00 + finger protection (VDE0106/100) | |
Memory protection | EEPROM (non-volatile memory)
Number of rewrites: 100,000 |
|
Applicable standards | UL61010-1, CSA C22.2 No. 61010-1-04
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II EN61326-1 |
|
EMC | EMI: EN61326-1 Industrial electromagnetic environment
Electromagnetic radiation interference: CISPR 11 Group 1, Class A Terminal interference voltage: CISPR 11 Group 1, Class A EMS: EN61326-1 Industrial electromagnetic environment Electrostatic Discharge Immunity: EN61000-4-2: 4 kV (contact), 8 kV (in air) Radiated Electromagnetic Field Immunity: EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Electrical Fast Transient/Burst Immunity: EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line) Surge Immunity: EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line) Conducted Disturbance Immunity: EN61000-4-6: 3 V (0.15 to 80 MHz) Power Frequency Magnetic Immunity: EN61000-4-8: 30 A/m (50 Hz) continuous time Voltage Dips and Interruptions Immunity: EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage) |
last update: August 6, 2015