|
G9SP
Safety Controller |
|
• Handles complex safety control
applications with easy programming.
• Create function blocks with applicable Support Software. Also
performs simulations.
• Restore design assets with Memory Cards without using a
computer.
|
EN
ISO13849-1:2008
EN ISO13849-2:2008
IEC61508 parts 1-7:2010
IEC/EN62061:2005
IEC 61131-2:2007
EN ISO13850:2008
(EN418:1992)
EN 60204-1:2006
EN 61000-6-2:2005
EN 61000-6-4:2007
NFPA 79-2007
ANSI RIA 15.06-1999
ANSI B11.19-2003
UL1998
UL508
CSA22.2 No. 142 |
• TÜV Rheinland
• UL (cUL)
|
|
G9SP Configurator |
|
• This programming software creates
safety circuits for the G9SP.
• Easy system configuration and I/O setup.
• Easy system verification with
simulations.
• Create software objects to greatly
reduce design work.
|
--- |
---
|
|
G9SX
Flexible Safety Unit |
|
• Logical AND connection enables partial or full control.
• Uses solid-state output (excluding Expansion Units).
• LED indicators provide details of failure diagnosis.
|
EN50178
ISO13849-1
EN954-1
IEC/EN60204-1
IEC/EN61508
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
CAN/CSA C22.2
No.142 |
• TÜV SÜD
• UL
• KOSHA
|
|
G9SX-GS
Safety Guard
Switching Unit |
|
• Auto Switching and Manual Switching functions support two types
of application.
• External indicator outputs enable indicating the switching
status of two safety input devices.
• Auxiliary outputs enable monitoring of safety inputs, safety
outputs, and errors.
• Detailed LED indications enable easy diagnosis.
• Logical AND connection allows complicated applications in
combination with other G9SX-series Units.
|
EN50178
IEC/EN60204-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
UL1998
NFPA79
IEC61508
CAN/CSA C22.2
No.142 |
• TÜV SÜD
• UL (cUL)
• KOSHA
|
|
G9SX-SM
Standstill Monitoring Unit |
|
• The back electromotive force (BEMF) signal is used to determine
when the motor has stopped.
• A standard configuration for standstill detection enables
immediate application without setup.
• User configuration to adjust settings for individual machines is
also possible.
• Detailed indicator displays for fault diagnosis.
• Certified for Safety Category 4 (EN 954-1), PLe (ISO 13849-1),
and SIL3 (IEC/EN 62061).
|
EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142 |
• TÜV SÜD
• UL (cUL)
|
|
G9SX-LM
Low-speed Monitoring
Unit |
|
• Detects the motor speed with a proximity sensor.
• Monitors to see if the motor is below the speed level that has
been set for the specific hazard source.
• Enable switch input provided for maintenance work.
• Detailed indicator displays for fault diagnosis.
• Certified for Safety Category 3 (EN 954-1), PLd (ISO 13849-1),
and SIL3 (IEC/EN 62061).
|
EN1088
EN50178
IEC/EN60204-1
ISO13849-1
EN954-1
IEC/EN61508
IEC/EN62061
IEC/EN61000-6-2
IEC/EN61000-6-4
UL508
CAN/CSA
C22.2 No.142 |
• TÜV SÜD
• UL (cUL)
|
|
G9SA
Safety Relay Unit |
|
• Compact design.
• Two-hand Controller model available.
• Simple connection of Expansion Unit.
• High-speed 10-ms response.
• Incorporates LED indicators for monitoring built-in relays.
• Finger protection construction.
• 3-pole, 5-pole and Off-delay Units available.
|
EN60204-1 ISO13849-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
• BG
• UL
• CSA
• CQC
|
|
G9SB
Safety Relay Unit |
|
• Ultra-compact, with models starting at only 17.5 mm wide.
• Can be used with Safety Sensors.
• High-speed 10-ms response.
• Incorporates LED indicators for monitoring built-in relays.
• Finger protection construction.
|
EN60204-1 ISO13849-1
EN954-1
UL508
CSA C22.2
No.14 GB14048.5 |
• TÜV Rheinland
• UL
• CSA
• CQC
|
|
F3SP-B1P
Control Unit for
Safety Sensor |
|
• Control Unit for F3SN-A, F3SN-B, F3SH-A, F3SR-B and F3SJ-B.
• Plug in light curtain connectors on both sides.
|
TÜV SÜD and UL certified in a set with F3SN-A, F3SN-B, and F3SH-A.
|