Small Limit Switch
last update: December 27, 2013
Certification body | Standard | File No. |
---|---|---|
CCC | GB14048.5 | Consult your OMRON representative for details. |
UL * | UL508, CSA C22.2 No. 14 | |
TÜV | IEC60947-5-1 |
* Certification equivalent to CSA C22.2 No. 14 has been obtained from UL.
Rated voltage
(V) |
Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC
250 VAC |
5
5 |
1.5
1 |
0.7
0.5 |
3
3 |
2
1.5 |
1
0.8 |
||
12 VDC
24 VDC |
5
5 |
3
3 |
4
4 |
3
3 |
||||
125 VDC
250 VDC |
0.4
0.4 |
0.2
0.2 |
---
--- |
---
--- |
---
--- |
Inrush current | NC | 24 A max. |
---|---|---|
NO | 12 A max. |
Category and rating |
---|
AC-12: 250 VAC at 5 A, resistive load
DC-12: 125 VDC at 0.4 A, resistive load |
Ratings |
---|
5 A, 250 VAC
0.4 A, 125 VDC |
Degree of protection | IP65 | |
---|---|---|
Durability
(See note 3.) |
Mechanical | 10,000,000 operations min. |
Electrical | 300,000 operations min. (5 A at 250 VAC, resistive load) | |
Operating speed | 5 mm to 0.5 m/s | |
Operating frequency | Mechanical | 120 operations/min |
Electrical | 30 operations/min | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 25 mΩ max. (initial value) | |
Dielectric strength | Between terminals of the
same polarity |
1,000 VAC, 50/60 Hz for 1 min |
Between currentcarrying
metal parts and ground |
1,500 VAC, 50/60 Hz for 1 min | |
Rated insulation voltage (Ui) | 250 V | |
Pollution degree (application environment) | 3 (EN 60947-5-1) | |
Short-circuit protection device | 10-A fuse, gG or gI (IEC 269) | |
Conditional short-circuit current | 100 A (EN 60947-5-1) | |
Rated open thermal current (lth) | 5 A (EN 60947-5-1) | |
Electric shock protection class | Class I | |
Rated frequency | 50/60 Hz | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude (See note 4.) |
Shock resistance | Destruction | 1,000 m/s2 (free position) min. |
Malfunction | 300 m/s2 (operation limit position) min. (See note 4.) | |
Ambient operating temperature range | -20°C to 60°C (with no icing) | |
Ambient operating humidity range | 90% max. | |
Weight | Approx. 130 to 190 g |
Model | D4V-8104Z | D4V-8107Z | D4V-8108Z | D4V-8111Z | |
---|---|---|---|---|---|
Operating characteristics | |||||
Operating force | OF max. | 5.88 N | 5.88 N | 7.84 N | 9.8 N |
Release force | RF min. | 0.49 N | 0.69 N | 0.49 N | 2.94 N |
Pretravel | PT max. | 20° | 20° | 20° | 1.5 mm |
Overtravel | OT min. | 75° | 75° | 75° | 4 mm |
Movement differential | MD max. | 10° | 10° | 10° | 1.2 mm |
Total travel | TT min. | 95° | 95° | 95° | 5.5 mm |
Operating position | OP | --- | --- | --- | 26±0.8 mm |
Model | D4V-8112Z | D4V-8122Z | D4V-8166Z | D4V-8169Z | |
---|---|---|---|---|---|
Operating characteristics | |||||
Operating force | OF max. | 9.8 N | 9.8 N | 0.88 N | 0.88 N |
Release force | RF min. | 2.94 N | 2.94 N | --- | --- |
Pretravel | PT max. | 1.5 mm | 1.5 mm | 30 mm | 30 mm |
Overtravel | OT min. | 4 mm | 4 mm | --- | --- |
Movement differential | MD max. | 1.2 mm | 1.2 mm | --- | --- |
Total travel | TT min. | 5.5 mm | 5.5 mm | --- | --- |
Operating position | OP | 37±0.8 mm | 37±0.8 mm | --- | --- |
last update: December 27, 2013