Digital Panel Meter Topic: Steps to Reduce Noise

 

FAQ No. FAQ00833

 

Question

What steps can be taken to reduce noise?


Answer


1. Noise Countermeasures

Do not install the Digital Panel Meter near devices that produce surges or high-frequency noise.

Mount a surge suppressor or noise filter to peripheral devices that generate noise, especially devices with a high inductance, such as motors, transformers, solenoids, and magnet coils.

 

Line filter and surge absorber circuit diagram

In order to prevent inductive noise, wire the lines connected to the terminal block separately from power lines carrying high voltages or currents. Do not wire in parallel with or in the same cable as power lines. Other measures for reducing noise include running lines along separate ducts and using shielded lines.


If a noise filter is used for the power supply, check the voltage and current, and install the noise filter as close to the product as possible.

 


2. Analog Signal Input


2-core shielded wire


Applicable Model: K3HB-X, K3HB-V, K3HB-S, K3GN, K3MA-J, K3TE, K3TF
 


3. Temperature Input

To prevent the effects of inductance in the lead wires between the Temperature Sensor and Digital Panel Meter, wire leads separately from power lines or load lines.

Reception interference may occur if the product is used too close to a radio, television, or wireless device.

Applicable Model: K3HB-H, K3MA-L

 

 